Monte Carlo Simulation of Multi-Head Si/CdTe Compton Camera for Medical Imaging

被引:0
|
作者
Yamaguchi, M. [1 ,2 ]
Kawachi, N. [3 ]
Watanabe, S. [2 ]
Odaka, H. [2 ]
Takeda, S. [2 ]
Ishikawa, S. [2 ]
Aono, H. [2 ]
Takahashi, T. [2 ]
Arakawa, K. [1 ,3 ]
Nakano, T. [1 ]
机构
[1] Gunma Univ, 21st Century COE Program, 3-39-22 Shouwa Machi, Gunma 3718511, Japan
[2] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2298510, Japan
[3] Japan Atom Energy Agcy, Takasaki Adv Radiat Res Inst, Takasaki, Gunma 3701292, Japan
关键词
CDTE DETECTOR; PERFORMANCE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a prototype of Compton camera using Si/CdTe semiconductors for medical imaging. In the case where a Compton camera has a single head and therefore the detection area of the Compton camera is restricted to small region, position resolution of depth direction is expected to be low. To overcome this weakness, we propose multi-head Compton camera. In this work, we evaluated the position resolutions of single- and double-head Compton camera by using Monte Carlo simulation. Consequently, the position resolution is about 6 mm for double-head camera while the position resolution of depth direction is about 15 mm for single-head camera. These results indicate that the position resolution is improved and clear 3D-image is taken by using multi-head Compton camera.
引用
收藏
页码:3275 / +
页数:2
相关论文
共 50 条
  • [1] Development of head module for multi-head Si/CdTe Compton camera for medical applications
    Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency , 1233 Watanuki-machi, Takasaki, Gunma, 370-1292, Japan
    不详
    不详
    不详
    不详
    不详
    不详
    [J]. Nucl Instrum Methods Phys Res Sect A, SUPPL. 1 (S2-S7):
  • [2] Development of head module for multi-head Si/CdTe Compton camera for medical applications
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Suzui, Nobuo
    Fujimaki, Shu
    Kamiya, Tomihiro
    Odaka, Hirokazu
    Ishikawa, Shin-nosuke
    Kokubun, Motohide
    Watanabe, Shin
    Takahashi, Tadayuki
    Shimada, Hirofumi
    Arakawa, Kazuo
    Suzuki, Yoshiyuki
    Torikai, Kota
    Yoshida, Yukari
    Nakano, Takashi
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S2 - S7
  • [3] Spatial Resolution of Multi-Head Si/CdTe Compton Camera for Medical Application
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Watanabe, Shigeki
    Satoh, Takahiro
    Shimada, Hirofumi
    Yoshida, Yukari
    Suzuki, Yoshiyuki
    Watanabe, Shin
    Takeda, Shin-ichiro
    Aono, Hiroyuki
    Ishikawa, Shin-nosuke
    Odaka, Hiyokazu
    Takahashi, Tadayuki
    Arakawa, Kazuo
    Nakano, Takashi
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4001 - +
  • [4] Monte Carlo simulation study on medical imaging of a multiply stacked Compton camera
    Kim, N. Y.
    Lee, C. S.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (02) : 1201 - 1204
  • [5] Performance study of Si/CdTe semiconductor Compton telescopes with Monte Carlo simulation
    Odaka, Hirokazu
    Takeda, Shin'ichiro
    Watanabe, Shin
    Ishikawa, Shin-nosuke
    Ushio, Masayoshi
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 878 - 885
  • [6] Simulation of Compton camera imaging with a specific purpose Monte Carlo code
    Earnhart, J
    Prettyman, T
    Lestone, J
    Gardner, R
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 673 - 680
  • [7] Basic Characteristics of a Newly Developed Si/CdTe Compton Camera for Medical Imaging
    Kawachi, N.
    Watanabe, S.
    Satoh, T.
    Arakawa, K.
    Takeda, S.
    Ishikawa, S.
    Aono, H.
    Watanabe, S.
    Yamaguchi, M.
    Takahashi, T.
    Shimada, H.
    Yoshida, Y.
    Suzuki, Y.
    Sakurai, H.
    Nakano, T.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 815 - +
  • [8] Development of semiconductor imaging detectors for a Si/CdTe Compton camera
    Watanabe, Shin
    Takeda, Shin'ichiro
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Ushio, Masayoshi
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 871 - 877
  • [9] Evaluation and optimization of geometry parameters of GAGG scintillator-based Compton Camera for medical imaging by Monte Carlo simulation
    Zarei, H.
    Razaghi, S.
    Nagao, Y.
    Itoh, M.
    Yamaguchi, M.
    Kawachi, N.
    Ay, M. R.
    Watabe, H.
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (01)
  • [10] Si/CdTe semiconductor Compton camera
    Watanabe, S
    Tanaka, T
    Nakazawa, K
    Mitani, T
    Oonuki, K
    Takahashi, T
    Takashima, T
    Tajima, H
    Fukazawa, Y
    Normachi, M
    Kubo, S
    Onishi, M
    Kuroda, Y
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4286 - 4290