Post-earthquake fire performance of square concrete-filled steel tube columns

被引:15
|
作者
Wang, Yu-Hang [1 ,2 ]
Tang, Qi [3 ]
Su, Mei-Ni [4 ]
Tan, Ji-Ke [2 ]
Wang, Wei-Yong [2 ]
Lan, Yong-Sen [5 ]
Luo, Wei [5 ]
Zhou, Yang [5 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
[4] Univ Manchester, Dept Mech Aerosp & Civil Engn, Manchester M1 3NJ, Lancs, England
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing 401122, Peoples R China
关键词
Design method; Finite element; Fire resistance; Seismic damage; Square concrete-filled steel tube; STRUCTURAL PERFORMANCE; BEHAVIOR; RESISTANCE; DESIGN; BEAMS; MODEL;
D O I
10.1016/j.tws.2020.106873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been shown that fire disaster normally occurs following an earthquake disaster, which might cause even more serious losses than the earthquake itself. This study investigates the post-earthquake fire performance of concrete-filled steel tube (CFST) columns. The experimental programme contains two parts - quasi-static tests and fire tests. During the quasi-static tests, the square CFST columns were loaded under constant compressive force and cyclic horizontal force, until reaching different degrees of seismic damage. Afterwards, the pre-damaged columns were loaded under a constant axial compression ratio (i.e. ratio of the applied compressive load to its bearing capacity) of 0.3 at elevated temperatures. The fire resistance time and failure modes of these pre-damaged CFST columns were reported. Finite element (FE) models were developed and validated against the test results; a total of 48 numerical results were generated in the parametric study using the validated model. In the parametric study, the influence of key parameters including the thickness of steel tube, the yield strength of steel tube, the axial compression ratio and pre-damage degrees on the fire resistance of square CFST columns were analysed. The experimental and numerical results are used to propose design rules for the fire performance of square CFST columns with different degrees of seismic damage.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [41] Fire performance of concrete-filled tubular columns
    Lie, TT
    Kodur, VKR
    INTERNATIONAL CONFERENCE ON TUBULAR STRUCTURES, PROCEEDINGS, 1996, : 86 - 96
  • [42] Review of fire performance experiment of concrete-filled steel tubular columns
    Xiang, Kai
    Wang, Guohui
    Pan, Yanchong
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 1397 - 1401
  • [43] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Tao, Zhong
    Wang, Zhi-Bin
    Han, Lin-Hai
    Uy, Brian
    STEEL AND COMPOSITE STRUCTURES, 2011, 11 (04): : 307 - 324
  • [44] Low cyclic fatigue performance of concrete-filled steel tube columns
    Qin Peng
    Tan Yang
    Xiao Yan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (10) : 4035 - 4042
  • [45] Low cyclic fatigue performance of concrete-filled steel tube columns
    秦鹏
    谭杨
    肖岩
    Journal of Central South University, 2015, 22 (10) : 4035 - 4042
  • [46] Low cyclic fatigue performance of concrete-filled steel tube columns
    Peng Qin
    Yang Tan
    Yan Xiao
    Journal of Central South University, 2015, 22 : 4035 - 4042
  • [47] Compressive performance of bamboo scrimber and concrete-filled steel tube columns
    Wei, Baoxing
    Wei, Yang
    Wang, Gaofei
    Xing, Ze
    Lin, Yu
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2024, 41 (06): : 3115 - 3128
  • [48] Seismic performance of recycled aggregate concrete-filled steel tube columns
    Tang, Yun-Chao
    Li, Li-Juan
    Feng, Wen-Xian
    Liu, Feng
    Liao, Bin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 112 - 124
  • [49] Compressive performance of bamboo scrimber and concrete-filled steel tube columns
    Wei, Baoxing
    Wei, Yang
    Lin, Yu
    Wang, Gaofei
    Zhang, Yirui
    ENGINEERING STRUCTURES, 2024, 300
  • [50] Research on concrete-filled square steel tubular columns
    Zhang, ZG
    MULTI-PURPOSE HIGH-RISE TOWERS AND TALL BUILDINGS, 1997, : 157 - 168