Post-earthquake fire performance of square concrete-filled steel tube columns

被引:15
|
作者
Wang, Yu-Hang [1 ,2 ]
Tang, Qi [3 ]
Su, Mei-Ni [4 ]
Tan, Ji-Ke [2 ]
Wang, Wei-Yong [2 ]
Lan, Yong-Sen [5 ]
Luo, Wei [5 ]
Zhou, Yang [5 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
[4] Univ Manchester, Dept Mech Aerosp & Civil Engn, Manchester M1 3NJ, Lancs, England
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing 401122, Peoples R China
关键词
Design method; Finite element; Fire resistance; Seismic damage; Square concrete-filled steel tube; STRUCTURAL PERFORMANCE; BEHAVIOR; RESISTANCE; DESIGN; BEAMS; MODEL;
D O I
10.1016/j.tws.2020.106873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been shown that fire disaster normally occurs following an earthquake disaster, which might cause even more serious losses than the earthquake itself. This study investigates the post-earthquake fire performance of concrete-filled steel tube (CFST) columns. The experimental programme contains two parts - quasi-static tests and fire tests. During the quasi-static tests, the square CFST columns were loaded under constant compressive force and cyclic horizontal force, until reaching different degrees of seismic damage. Afterwards, the pre-damaged columns were loaded under a constant axial compression ratio (i.e. ratio of the applied compressive load to its bearing capacity) of 0.3 at elevated temperatures. The fire resistance time and failure modes of these pre-damaged CFST columns were reported. Finite element (FE) models were developed and validated against the test results; a total of 48 numerical results were generated in the parametric study using the validated model. In the parametric study, the influence of key parameters including the thickness of steel tube, the yield strength of steel tube, the axial compression ratio and pre-damage degrees on the fire resistance of square CFST columns were analysed. The experimental and numerical results are used to propose design rules for the fire performance of square CFST columns with different degrees of seismic damage.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [31] Compressive behavior of concrete-filled square stainless steel tube stub columns
    Dai, Peng
    Yang, Lu
    Wang, Jie
    Ning, Keyang
    Gang, Yi
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (01): : 91 - 106
  • [32] Enhancing the fire-resistant performance of concrete-filled steel tube columns with steel fiber-reinforced concrete
    George, Christo
    Selvan, S. Senthil
    Kumar, V. Sathish
    Murali, G.
    Giri, Jayant
    Makki, Emad
    Sathish, T.
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [33] The interaction of steel tube and concrete core in concrete-filled steel tube columns
    Starossek, U.
    Falah, N.
    TUBULAR STRUCTURES XII, 2009, : 75 - +
  • [34] Seismic Performance of Hybrid Columns of Concrete-Filled Square Steel Tube with FRP-Confined Concrete Core
    Feng, Peng
    Cheng, Shi
    Yu, Tao
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (04)
  • [35] Numerical Simulation of the Fire Response of a Frame with Concrete-Filled Steel Tube Columns
    Bao, Yanhong
    Li, Jierong
    Xu, Lei
    FIRE TECHNOLOGY, 2024, 60 (05) : 3059 - 3089
  • [36] Stability Behavior of Concrete-Filled Steel Tube Columns in Real Fire Conditions
    Taddhanpally, Shashank
    Agarwal, Anil
    STRUCTURES IN FIRE, 2016, : 527 - 534
  • [37] RESISTANCE OF CONCRETE-FILLED, FIRE-RESISTANT STEEL-TUBE COLUMNS
    SAKUMOTO, Y
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1994, 6 (02) : 169 - 184
  • [38] Seismic performance of steel moment frame office buildings with square concrete-filled steel tube gravity columns
    Judd, Johnn P.
    Pakwan, Nipun
    ENGINEERING STRUCTURES, 2018, 172 : 41 - 54
  • [39] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Civionics Research Centre, University of Western Sydney, Penrith, NSW 2751, Australia
    不详
    不详
    Steel Compos. Struct., 4 (307-324):
  • [40] Performance of high strength concrete-filled steel columns exposed to fire
    Kodur, VKR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1998, 25 (06) : 975 - 981