Post-earthquake fire performance of square concrete-filled steel tube columns

被引:15
|
作者
Wang, Yu-Hang [1 ,2 ]
Tang, Qi [3 ]
Su, Mei-Ni [4 ]
Tan, Ji-Ke [2 ]
Wang, Wei-Yong [2 ]
Lan, Yong-Sen [5 ]
Luo, Wei [5 ]
Zhou, Yang [5 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
[4] Univ Manchester, Dept Mech Aerosp & Civil Engn, Manchester M1 3NJ, Lancs, England
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing 401122, Peoples R China
关键词
Design method; Finite element; Fire resistance; Seismic damage; Square concrete-filled steel tube; STRUCTURAL PERFORMANCE; BEHAVIOR; RESISTANCE; DESIGN; BEAMS; MODEL;
D O I
10.1016/j.tws.2020.106873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been shown that fire disaster normally occurs following an earthquake disaster, which might cause even more serious losses than the earthquake itself. This study investigates the post-earthquake fire performance of concrete-filled steel tube (CFST) columns. The experimental programme contains two parts - quasi-static tests and fire tests. During the quasi-static tests, the square CFST columns were loaded under constant compressive force and cyclic horizontal force, until reaching different degrees of seismic damage. Afterwards, the pre-damaged columns were loaded under a constant axial compression ratio (i.e. ratio of the applied compressive load to its bearing capacity) of 0.3 at elevated temperatures. The fire resistance time and failure modes of these pre-damaged CFST columns were reported. Finite element (FE) models were developed and validated against the test results; a total of 48 numerical results were generated in the parametric study using the validated model. In the parametric study, the influence of key parameters including the thickness of steel tube, the yield strength of steel tube, the axial compression ratio and pre-damage degrees on the fire resistance of square CFST columns were analysed. The experimental and numerical results are used to propose design rules for the fire performance of square CFST columns with different degrees of seismic damage.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [21] Post-fire behaviour and resistances of square recycled aggregate concrete-filled stainless steel tube stub columns
    Wang, Ziyi
    Zhong, Yukai
    Jiang, Ke
    Su, Meini
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2024, 197
  • [22] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [23] The performance of concrete filled steel tube columns under post earthquake fires
    Talebi, Elnaz
    Korzen, Manfred
    Hothan, Sascha
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 115 - 128
  • [24] Experimental study on ductility of square concrete-filled steel tube columns
    Du Xikai
    Wang Tiecheng
    Shen Dongjian
    Zhang Zhenkun
    8th International Conference on Steel-Concrete Composite and Hybrid Structures, Proceedings, 2006, : 73 - 78
  • [25] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Mohamed Ghannam
    Tian Yi Song
    Fire Technology, 2021, 57 : 911 - 942
  • [26] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Ghannam, Mohamed
    Song, Tian Yi
    FIRE TECHNOLOGY, 2021, 57 (02) : 911 - 942
  • [27] A Study on Fire Resistance of Reinforced Concrete-filled Square Steel Columns Exposed to Fire
    Park, Su Hee
    Song, Kyung Chul
    Choi, Sung Mo
    Won, Yong Ahn
    Bang, Joong Seck
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 501 - 508
  • [28] Post-fire flexural buckling and resistances of square recycled aggregate concrete-filled stainless steel tube (RACFSST) columns
    Wang, Ziyi
    Zhong, Yukai
    Su, Andi
    Su, Meini
    Zhao, Ou
    Thin-Walled Structures, 2024, 205
  • [29] The hysteretic behavior of recycled aggregate concrete-filled square steel tube columns
    Zhang, Xianggang
    Gao, Xiang
    ENGINEERING STRUCTURES, 2019, 198
  • [30] A study on the behavior of eccentrically compressed square concrete-filled steel tube columns
    Lu, F. W.
    Li, S. P.
    Sun, Guojun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (07) : 941 - 948