Fire performance of concrete-filled steel tubular columns strengthened by CFRP

被引:1
|
作者
Tao, Zhong [1 ,2 ]
Wang, Zhi-Bin [2 ]
Han, Lin-Hai [3 ]
Uy, Brian [1 ]
机构
[1] Univ Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
[2] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian Province, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
来源
STEEL AND COMPOSITE STRUCTURES | 2011年 / 11卷 / 04期
基金
高等学校博士学科点专项科研基金;
关键词
concrete-filled steel tubes (CFST); fibre reinforced polymer (FRP); strengthening; columns; insulation; confinement; fire endurance; BEHAVIOR; RESISTANCE; PROTECTION; ENDURANCE; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.
引用
收藏
页码:307 / 324
页数:18
相关论文
共 50 条
  • [1] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Civionics Research Centre, University of Western Sydney, Penrith, NSW 2751, Australia
    不详
    不详
    Steel Compos. Struct., 4 (307-324):
  • [2] Structural performance of CFRP-strengthened concrete-filled stainless steel tubular short columns
    Sharif, Alfarabi M.
    Al-Mekhlafi, Galal M.
    Al-Osta, Mohammed A.
    ENGINEERING STRUCTURES, 2019, 183 : 94 - 109
  • [3] Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns
    Tao, Zhong
    Han, Lin-Hai
    Zhuang, Jin-Ping
    ADVANCES IN STRUCTURAL ENGINEERING, 2007, 10 (01) : 37 - 46
  • [4] Fire performance of concrete-filled tubular columns
    Lie, TT
    Kodur, VKR
    INTERNATIONAL CONFERENCE ON TUBULAR STRUCTURES, PROCEEDINGS, 1996, : 86 - 96
  • [5] Review of fire performance experiment of concrete-filled steel tubular columns
    Xiang, Kai
    Wang, Guohui
    Pan, Yanchong
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 1397 - 1401
  • [6] Fire performance on steel-reinforced concrete-filled steel tubular columns with fire protection
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [7] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [8] Fire behavior and performance of concrete-filled steel tubular columns: Review and discussion
    Wang, J. H.
    He, J.
    Xiao, Y.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 157 : 19 - 31
  • [9] High strength concrete-filled tubular steel columns in fire
    Bahr, O.
    TUBULAR STRUCTURES XII, 2009, : 461 - 467
  • [10] Cyclic performance of fire-damaged concrete-filled steel tubular beam-columns repaired with CFRP wraps
    Tao, Zhong
    Han, Lin-Hai
    Zhuang, Jin-Ping
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (01) : 37 - 50