Fire performance of concrete-filled steel tubular columns strengthened by CFRP

被引:1
|
作者
Tao, Zhong [1 ,2 ]
Wang, Zhi-Bin [2 ]
Han, Lin-Hai [3 ]
Uy, Brian [1 ]
机构
[1] Univ Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
[2] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian Province, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
来源
STEEL AND COMPOSITE STRUCTURES | 2011年 / 11卷 / 04期
基金
高等学校博士学科点专项科研基金;
关键词
concrete-filled steel tubes (CFST); fibre reinforced polymer (FRP); strengthening; columns; insulation; confinement; fire endurance; BEHAVIOR; RESISTANCE; PROTECTION; ENDURANCE; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.
引用
收藏
页码:307 / 324
页数:18
相关论文
共 50 条
  • [41] Research on concrete-filled square steel tubular columns
    Zhang, ZG
    MULTI-PURPOSE HIGH-RISE TOWERS AND TALL BUILDINGS, 1997, : 157 - 168
  • [42] Constitutive relation of concrete of concrete-filled CFRP-steel tubular short columns with axial compression
    Gu, Wei
    Li, Hong-Nan
    Zhang, Mei-Na
    Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 2011, 51 (04): : 545 - 548
  • [43] Fire Performance of Steel Tubular Columns Filled with Normal Strength Concrete
    Szymkuc, Wojciech
    Glema, Adam
    Malendowski, Michal
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 865 - 872
  • [44] Fire performance of concrete filled steel tubular beam-columns
    Han, LH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 695 - 709
  • [45] Experimental study on steel-reinforced concrete-filled steel tubular columns under the fire
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    Du, Er-Feng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185 (185)
  • [46] Temperatures in unprotected joints between steel beams and concrete-filled tubular columns in fire
    Ding, J.
    Wang, Y. C.
    FIRE SAFETY JOURNAL, 2009, 44 (01) : 16 - 32
  • [47] Fire Resistance Tests on Concrete-Filled Steel Tubular Columns with Geopolymeric Recycled Aggregate
    Tian-Yi Song
    Xing-Yu Qu
    Zhu Pan
    Kai Xiang
    Hongyuan Zhou
    Fire Technology, 2022, 58 : 2727 - 2754
  • [48] Seismic Performance of Reinforced Concrete Beam to Concrete-filled Steel Tubular Columns Joints
    Qu, Hui
    Han, Lin-Hai
    Tao, Zhong
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 685 - +
  • [49] Effects of boundary restraints on concrete-filled steel tubular columns with reinforcements exposed to fire
    Guo, Zhen
    Wang, Xing
    Zhang, Xuecheng
    Song, Jun
    Li, Chenfeng
    THIN-WALLED STRUCTURES, 2019, 142 : 52 - 63
  • [50] Seismic behavior of fire-exposed concrete-filled steel tubular (CFST) columns
    Li, Shuai
    Han, Lin-Hai
    Wang, Fa-Cheng
    Hou, Chuan-Chuan
    Han, Lin-Hai (lhhan@tsinghua.edu.cn), 1600, Elsevier Ltd (224):