Fire performance of concrete-filled steel tubular columns strengthened by CFRP
被引:1
|
作者:
Tao, Zhong
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian Province, Peoples R ChinaUniv Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
Tao, Zhong
[1
,2
]
Wang, Zhi-Bin
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian Province, Peoples R ChinaUniv Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
Wang, Zhi-Bin
[2
]
Han, Lin-Hai
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R ChinaUniv Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
Han, Lin-Hai
[3
]
Uy, Brian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Sydney, Civ Res Ctr, Penrith, NSW 2751, AustraliaUniv Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
Uy, Brian
[1
]
机构:
[1] Univ Western Sydney, Civ Res Ctr, Penrith, NSW 2751, Australia
[2] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian Province, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.
机构:
Shanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China
Univ Auckland, Dept Civil & Environm Engn, Auckland, New ZealandShanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China
Meng, Fan-Qin
Zhu, Mei-Chun
论文数: 0引用数: 0
h-index: 0
机构:
Shanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R ChinaShanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China
Zhu, Mei-Chun
Clifton, G. Charles
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Dept Civil & Environm Engn, Auckland, New ZealandShanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China
Clifton, G. Charles
Ukanwa, Kingsley U.
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China
Ukanwa, Kingsley U.
Lim, James B. P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Dept Civil & Environm Engn, Auckland, New ZealandShanghai Normal Univ, Dept Civil Engn, Shanghai, Peoples R China