Comparison of Axial Performance of Cone-Beam Reconstruction Algorithms for Off-Center Flat-Panel Imaging with a SPECT System

被引:0
|
作者
Konate, Souleymane [1 ]
Pretorius, P. Hendrik [1 ]
Mukherjee, Joyeeta Mitra [1 ]
Dey, Joyoni [1 ]
Ritacco, Alan [1 ]
Glick, Stephen [1 ]
O'Connor, J. Michael [1 ]
Shao, Lingxiong [2 ]
Wang, Jiong [2 ]
Feng, Bing
King, Michael A. [1 ]
机构
[1] Univ Massachusetts, Sch Med, Worcester, MA 01605 USA
[2] Philips Med Syst, San Jose, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
a In this paper, using Defrise Phantoms, we present our investigations of the axial limitations of an analytical cone-beam reconstruction algorithm (FDK), and the iterative ordered-subset transmission reconstruction (OSTR) iterative algorithm, for an axially extended version of the Philips Brightview XCT cone beam CT (CBCT) geometry. Simulations were preformed for head size and body size Defrise Phantoms of different axial dimensions to investigate limitations on axial extent as a function of these. OSTR yielded overall better axial performance than FDK. It may be possible to reconstruct a larger axial extent for brain studies; however, patients with larger body sizes pose more of a problem.
引用
收藏
页码:3483 / 3491
页数:9
相关论文
共 50 条
  • [1] Iterative cone-beam CT reconstruction with an off-center flat-panel detector for SPECT/CT
    Hansis, Eberhard
    Sowards-Emmerd, David
    Hines, Horace
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [2] Comparison between Projection Weighting and Rebinning Approaches in Analytical Image Reconstruction in Off-Center Flat Panel Cone-Beam CT Imaging
    Amin, Adam Tan Mohd
    Abd Rahni, Ashrani Aizzuddin
    Mokri, Siti Salasiah
    Ahmad, Rozilawati
    [J]. 2018 2ND INTERNATIONAL CONFERENCE ON BIOSIGNAL ANALYSIS, PROCESSING AND SYSTEMS (ICBAPS 2018), 2018, : 33 - 36
  • [3] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [4] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [5] NEQ description of 3-D imaging performance in flat-panel cone-beam CT
    Siewerdsen, J
    Jaffray, D
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1321 - 1321
  • [6] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [7] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [8] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [9] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [10] Comparison of flat-panel detector with image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, M
    Ikeda, S
    [J]. RADIOLOGY, 2000, 217 : 405 - 405