Iterative cone-beam CT reconstruction with an off-center flat-panel detector for SPECT/CT

被引:0
|
作者
Hansis, Eberhard [1 ]
Sowards-Emmerd, David [1 ]
Hines, Horace [1 ]
Shao, Lingxiong [1 ]
机构
[1] Philips Healthcare, Nucl Med, San Jose, CA USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
247
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [2] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Comparison of Axial Performance of Cone-Beam Reconstruction Algorithms for Off-Center Flat-Panel Imaging with a SPECT System
    Konate, Souleymane
    Pretorius, P. Hendrik
    Mukherjee, Joyeeta Mitra
    Dey, Joyoni
    Ritacco, Alan
    Glick, Stephen
    O'Connor, J. Michael
    Shao, Lingxiong
    Wang, Jiong
    Feng, Bing
    King, Michael A.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3483 - 3491
  • [4] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [5] Comparison of flat-panel detector with image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, M
    Ikeda, S
    [J]. RADIOLOGY, 2000, 217 : 405 - 405
  • [6] Comparison of flat-panel detector and image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, K
    Ikeda, S
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 153 - 158
  • [7] Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector
    Zhao, Z.
    Gang, G. J.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [8] Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
    Tilley, Steven, II
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 296 - 319
  • [9] Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification
    Zbijewski, W.
    Gang, G. J.
    Xu, J.
    Wang, A. S.
    Stayman, J. W.
    Taguchi, K.
    Carrino, J. A.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [10] Comparison between Projection Weighting and Rebinning Approaches in Analytical Image Reconstruction in Off-Center Flat Panel Cone-Beam CT Imaging
    Amin, Adam Tan Mohd
    Abd Rahni, Ashrani Aizzuddin
    Mokri, Siti Salasiah
    Ahmad, Rozilawati
    [J]. 2018 2ND INTERNATIONAL CONFERENCE ON BIOSIGNAL ANALYSIS, PROCESSING AND SYSTEMS (ICBAPS 2018), 2018, : 33 - 36