Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions

被引:22
|
作者
Kovochich, Michael [1 ]
Fung, Ernest S. [1 ]
Donovan, Ellen [2 ,4 ]
Unice, Kenneth M. [3 ]
Paustenbach, Dennis J. [2 ]
Finley, Brent L. [2 ]
机构
[1] Cardno ChemRisk, Aliso Viejo, CA 92656 USA
[2] Cardno ChemRisk, San Francisco, CA 94105 USA
[3] Cardno ChemRisk, Pittsburgh, PA 15222 USA
[4] Ramboll Environ, San Francisco, CA USA
关键词
metal-on-metal; hip implant; wear debris; particle characterization; edge loading; inclination angle; microseparation; COBALT-CHROMIUM ALLOY; IN-VIVO DETERMINATION; PHYSICOCHEMICAL PROPERTIES; QUANTITATIVE-ANALYSIS; JOINT PROSTHESES; BEARING SURFACES; COCRMO-ALLOY; ION LEVELS; CUP ANGLE; PARTICLES;
D O I
10.1002/jbm.b.33902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40 degrees angle) and edge-loading (65 degrees angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (<100 nm) to submicron (<1000 nm) size range, whereas edge-loading conditions generated particles that ranged from <100 nm up to 3000-6000 nm in size. Particles isolated from normal wear were primarily chromium (98.5%) and round to oval in shape. Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. (c) 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018.
引用
收藏
页码:986 / 996
页数:11
相关论文
共 50 条
  • [1] The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing
    Mellon, S. J.
    Kwon, Y. -M.
    Glyn-Jones, S.
    Murray, D. W.
    Gill, H. S.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) : 1212 - 1220
  • [2] In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours
    Kwon, Y-M.
    Mellon, S. J.
    Monk, P.
    Murray, D. W.
    Gill, H. S.
    [J]. BONE & JOINT RESEARCH, 2012, 1 (04): : 42 - 49
  • [3] Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested In a physiological hip joint simulator
    Firkins, PJ
    Tipper, JL
    Saadatzadeh, MR
    Ingham, E
    Stone, MH
    Farrar, R
    Fisher, J
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2001, 11 (02) : 143 - 157
  • [4] Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions
    Al-Hajjar, Mazen
    Fisher, John
    Williams, Sophie
    Tipper, Joanne L.
    Jennings, Louise M.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (02) : 213 - 222
  • [5] What Is a "Normal" Wear Pattern for Metal-on-Metal Hip Bearings?
    Bowsher, J. G.
    Clarke, I. C.
    Williams, P. A.
    Donaldson, T. K.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 297 - 308
  • [6] The Otto Aufranc Award - Wear and lubrication of metal-on-metal hip implants
    Chan, FW
    Bobyn, JD
    Medley, JB
    Krygier, JJ
    Tanzer, M
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 10 - 24
  • [7] On the role of the lambda parameter in simulator wear of metal-on-metal hip implants
    Paré, P
    Medley, JB
    Chan, FW
    Young, SK
    [J]. TRIBOLOGICAL RESEARCH AND DESIGN FOR ENGINEERING SYSTEMS, 2003, : 281 - 290
  • [8] Simulator wear of some commercially available metal-on-metal hip implants
    Medley, JB
    Dowling, JM
    Poggie, RA
    Krygier, JJ
    Bobyn, JD
    [J]. ALTERNATIVE BEARING SURFACES IN TOTAL JOINT REPLACEMENT, 1998, 1346 : 92 - 110
  • [9] A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants
    Di Puccio, Francesca
    Mattei, Lorenza
    [J]. TRIBOLOGY INTERNATIONAL, 2015, 83 : 69 - 76
  • [10] Failure Modes of 433 Metal-on-Metal Hip Implants: How, Why, and Wear
    Ebramzadeh, Edward
    Campbell, Patricia A.
    Takamura, Karren M.
    Lu, Zhen
    Sangiorgio, Sophia N.
    Kalma, Jeremy J.
    De Smet, Koen A.
    Amstutz, Harlan C.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) : 241 - +