A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants

被引:19
|
作者
Di Puccio, Francesca [1 ]
Mattei, Lorenza [1 ]
机构
[1] Univ Pisa, Dept Civil & Ind Engn, I-56122 Pisa, Italy
关键词
Wear coefficient; Archard wear law; Wear predictive model; Hip replacement; CONTACT PRESSURE; JOINT SIMULATOR; CROSS-SHEAR; PREDICTION; LUBRICATION; PERFORMANCE; PROSTHESES; MOTION; LOAD;
D O I
10.1016/j.triboint.2014.10.023
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A novel approach is proposed to estimate and model the wear of metal-on-metal hip implants. The approach is based on two distinct wear coefficients for the head and cup, derived from separate measurements on the two components. This is in contrast to the usual assumption that a single wear coefficient (k) is valid for both bodies. Actually, the head and cup do not wear equally; thus, assuming equal wear leads to predictive errors. Additionally, in most papers, k is chosen considering only implant materials while neglecting geometry and testing conditions. It is suggested that experimental procedures designed for hip implants should measure the head and cup volume losses separately and that wear maps should be provided to validate numerical models. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [1] Simulator wear of some commercially available metal-on-metal hip implants
    Medley, John B.
    Dowling, Judith M.
    Poggie, Robert A.
    Krygier, Jan J.
    Bobyn, J. Dennis
    [J]. ASTM Special Technical Publication, 1999, (1346): : 92 - 110
  • [2] The Otto Aufranc Award - Wear and lubrication of metal-on-metal hip implants
    Chan, FW
    Bobyn, JD
    Medley, JB
    Krygier, JJ
    Tanzer, M
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 10 - 24
  • [3] On the role of the lambda parameter in simulator wear of metal-on-metal hip implants
    Paré, P
    Medley, JB
    Chan, FW
    Young, SK
    [J]. TRIBOLOGICAL RESEARCH AND DESIGN FOR ENGINEERING SYSTEMS, 2003, : 281 - 290
  • [4] Simulator wear of some commercially available metal-on-metal hip implants
    Medley, JB
    Dowling, JM
    Poggie, RA
    Krygier, JJ
    Bobyn, JD
    [J]. ALTERNATIVE BEARING SURFACES IN TOTAL JOINT REPLACEMENT, 1998, 1346 : 92 - 110
  • [5] Modern Metal-on-Metal Hip Implants
    Bozic, Kevin J.
    Browne, James
    Dangles, Chris J.
    Manner, Paul A.
    Yates, Adolph J., Jr.
    Weber, Kristy L.
    Boyer, Kevin M.
    Zemaitis, Paul
    Woznica, Anne
    Turkelson, Charles M.
    Wies, Janet L.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (06) : 402 - 406
  • [6] Failure Modes of 433 Metal-on-Metal Hip Implants: How, Why, and Wear
    Ebramzadeh, Edward
    Campbell, Patricia A.
    Takamura, Karren M.
    Lu, Zhen
    Sangiorgio, Sophia N.
    Kalma, Jeremy J.
    De Smet, Koen A.
    Amstutz, Harlan C.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) : 241 - +
  • [7] Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants
    Liu, F
    Jin, ZM
    Hirt, F
    Rieker, C
    Roberts, P
    Grigoris, P
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H5) : 319 - 328
  • [8] Stop-dwell-start motion: A novel simulator protocol for the wear of metal-on-metal hip implants
    Roter, GE
    Medley, JB
    Bobyn, JD
    Krygier, JJ
    Chan, FW
    [J]. BOUNDARY AND MIXED LUBRICATION: SCIENCE AND APPLICATIONS, 2002, 40 : 367 - 376
  • [9] Metal-on-metal hip implants and the risk of cancer
    Rosengren, Bjorn Erik
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2012, 345
  • [10] METAL-ON-METAL HIP IMPLANTS BMJ's reply to DePuy's criticisms of article on safety of metal-on-metal hip implants
    Cohen, Deborah
    [J]. BRITISH MEDICAL JOURNAL, 2012, 344