A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants

被引:19
|
作者
Di Puccio, Francesca [1 ]
Mattei, Lorenza [1 ]
机构
[1] Univ Pisa, Dept Civil & Ind Engn, I-56122 Pisa, Italy
关键词
Wear coefficient; Archard wear law; Wear predictive model; Hip replacement; CONTACT PRESSURE; JOINT SIMULATOR; CROSS-SHEAR; PREDICTION; LUBRICATION; PERFORMANCE; PROSTHESES; MOTION; LOAD;
D O I
10.1016/j.triboint.2014.10.023
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A novel approach is proposed to estimate and model the wear of metal-on-metal hip implants. The approach is based on two distinct wear coefficients for the head and cup, derived from separate measurements on the two components. This is in contrast to the usual assumption that a single wear coefficient (k) is valid for both bodies. Actually, the head and cup do not wear equally; thus, assuming equal wear leads to predictive errors. Additionally, in most papers, k is chosen considering only implant materials while neglecting geometry and testing conditions. It is suggested that experimental procedures designed for hip implants should measure the head and cup volume losses separately and that wear maps should be provided to validate numerical models. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [41] Carbon composition effects on wear behaviour and wear mechanisms of metal-on-metal hip prosthesis
    Ihaddadene, R.
    Affatato, S.
    Zavalloni, M.
    Bouzid, S.
    Viceconti, M.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 : 33 - 34
  • [42] Influence of cup orientation on the wear performance of metal-on-metal hip replacements
    Angadji, A.
    Royle, M.
    Collins, S. N.
    Shelton, J. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) : 449 - 457
  • [43] Concordance between laboratories in metal ion testing in patients with metal-on-metal hip implants
    Saini, Raghav
    Railton, Pam
    Boyd, Jessica
    Sadrzadeh, Hossein
    Powell, James N.
    [J]. CANADIAN JOURNAL OF SURGERY, 2019, 62 (01) : 9 - 13
  • [44] Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants
    Sampson, Barry
    Hart, Alister
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 118 - 131
  • [45] Massive wear of an incompatible metal-on-metal articulation in total hip arthroplasty
    Keel, JB
    Kuster, MS
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 638 - 642
  • [46] Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
    Lord, J. K.
    Langton, D. J.
    Nargol, A. V. F.
    Joyce, T. J.
    [J]. WEAR, 2011, 272 (01) : 79 - 87
  • [47] Wear of ceramic coated metal-on-metal bearings used for hip replacement
    Gispert, M. P.
    Serro, A. P.
    Colaco, R.
    Pires, E.
    Saramago, B.
    [J]. WEAR, 2007, 263 (7-12 SPEC. ISS.) : 1060 - 1065
  • [48] Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies
    Affatato, Saverio
    Traina, Francesco
    Ruggeri, Oddone
    Toni, Aldo
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (12): : 1155 - 1164
  • [49] Tribochemical Reactions in Metal-on-Metal Hip Joints Influence Wear and Corrosion
    Wimmer, Markus A.
    Mathew, Mathew T.
    Laurent, Michel P.
    Nagelli, Christopher
    Liao, Yifeng
    Marks, Laurence D.
    Pourzal, Robin
    Fischer, Alfons
    Jacobs, Joshua J.
    [J]. METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 292 - 309
  • [50] Development of computational wear simulation of metal-on-metal hip resurfacing replacements
    Liu, F.
    Leslie, I.
    Williams, S.
    Fisher, J.
    Jin, Z.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (03) : 686 - 694