Fast Nonlinear Deterministic Calibration of Pipelined A/D Converters

被引:0
|
作者
Oshima, Takashi [1 ]
Takahashi, Tomorni [1 ]
Yarnawaki, Taizo [1 ]
Tsang, Cheonguyen [2 ]
Stepanovic, Dusan [2 ]
Nikolic, Borivoje [2 ]
机构
[1] Hitachi Ltd, Cent Res Lab, 1-280 Higashi Koigakubo, Kokubunji, Tokyo 1858601, Japan
[2] Univ Calif Berkeley, Berkeley Wireless Res Ctr, Berkeley, CA 94704 USA
关键词
Pipelined ADC; digital calibration; convergence time; MDAC; redundancy;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The high-speed and high-resolution ADC is a key enabler for many future wireless communications systems. The digital background calibration technique can be used to reduce the total power consumption by enhancing the linearity without using high-gain amplifiers. One of the main practical constraints in the wireless applications is a short time available for calibration. This paper proposes a novel fast calibration method of pipelined ADCs, suitable for wireless communications applications, where a sufficiently high resolution can be achieved without requiring any calibration period.
引用
收藏
页码:914 / +
页数:2
相关论文
共 50 条
  • [1] A Fast Simulator for Pipelined A/D Converters
    Sahoo, Bibhu Datta
    Razavi, Behzad
    2009 52ND IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 2009, : 402 - 406
  • [2] Digital calibration for monotonic pipelined A/D converters
    Guo, HJ
    Law, W
    Helms, J
    Allstot, DJ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (06) : 1485 - 1492
  • [3] A Calibration Method of SFDR Based on INL for Pipelined A/D Converters
    Liu, Tao
    Chen, Liang
    Liu, Lu
    Xu, Daiguo
    Wang, Xu
    Shi, Hanfu
    Deng, Minming
    2014 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2014,
  • [4] Background calibration of operational amplifier gain error in pipelined A/D converters
    Ali, AMA
    Nagaraj, K
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 2003, 50 (09): : 631 - 634
  • [5] Foreground Digital Calibration of Non-linear Errors in Pipelined A/D Converters
    Adel, Hussein
    Dessouky, Mohamed
    Louerat, Marie-Minerve
    Gicquel, Hugo
    Haddara, Hisham
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 569 - 572
  • [6] A Histogram-Based Digital Background Calibration Technique for Pipelined A/D Converters
    Yahyaee, Saeedeh
    Yavari, Mohammad
    2022 IRANIAN INTERNATIONAL CONFERENCE ON MICROELECTRONICS, IICM, 2022, : 80 - 84
  • [7] Reference-Free Deterministic Calibration of Pipelined ADC
    Oshima, Takashi
    Yamawaki, Taizo
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2015, E98A (02) : 665 - 675
  • [8] Functional simulation of a technique for background calibration of capacitor mismatch errors in pipelined A/D converters
    Chiorboli, G
    Morandi, C
    MEASUREMENT, 2006, 39 (03) : 204 - 212
  • [9] A Semiblind Digital-Domain Calibration of Pipelined A/D Converters via Convex Optimization
    Kim, Jintae
    Lee, Minjae
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2015, 23 (07) : 1375 - 1379
  • [10] A monotonic digital calibration technique for pipelined data converters
    Law, WS
    Guo, JJ
    Peach, CT
    Helms, WJ
    Allstot, DJ
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL I: ANALOG CIRCUITS AND SIGNAL PROCESSING, 2003, : 873 - 876