Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo

被引:0
|
作者
Chuah, K. W. [1 ]
Aziz, Abdul M. Z. [2 ]
Jayamani, J. [1 ]
机构
[1] Univ Sains Malaysia, Sch Hlth Sci, Med Radiat Programme, Hlth Campus, Kubang Kerian 16150, Kelantan, Malaysia
[2] Univ Sains Malaysia, Adv Med & Dent Inst, Dept Biomed Imaging, Kepala Batas 13200, Pulau Pinang, Malaysia
关键词
Collimator scatter factor; phantom scatter factor; linear accelerator; SIMULATION; SIZE;
D O I
10.4103/jmp.jmp_40_22
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accuracy of ionization chamber (IC) to measure the scatter output factor (Scp) of a linear accelerator (linac) is crucial, especially in small field (<4 cm x 4 cm). The common IC volume of 0.6 cc is not adequate for small-field measurement and not all radiotherapy centers can afford to purchase additional IC due to the additional cost. This study aimed to determine the efficiency of the EGSnrc Monte Carlo (MC) to calculate the Scp for various field sizes including small field in Elekta Synergy (Agility multileaf collimator) linac. The BEAMnrc and DOSXYZnrc user codes were used to simulate a 6 MV linac model for various field sizes and calculate the radiation dose output in water phantom. The modeled linac treatment head was validated by comparing the percentage depth dose (PDD), beam profile, and beam quality (Tissue Phantom Ratio (TPR)20,10) with the IC measurement. The validated linac model was simulated to calculate the Scp consisting of collimator scatter factor (Sc) and phantom scatter factor (Sp). The PDD and beam profile of the simulated field sizes were within a good agreement of +/- 2% compared with the measured data. The TPR20,10 value was 0.675 for field size 10 cm x 10 cm. The Scp, Sc, and Sp simulated values were close to the IC measurement within +/- 2% difference. The simulation for Sc and Sp in 3 cm x 3 cm field size was calculated to be 0.955 and 0.884, respectively. In conclusion, this study validated the efficiency of the MC simulation as a promising tool for the Scp calculation including small-field size for linac.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 50 条
  • [1] Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam
    Fukata K.
    Sugimoto S.
    Kurokawa C.
    Saito A.
    Inoue T.
    Sasai K.
    [J]. Radiological Physics and Technology, 2018, 11 (2) : 192 - 201
  • [2] Determination of output factor for 6 MV small photon beam: comparison between Monte Carlo simulation technique and microDiamond detector
    Krongkietlearts, K.
    Tangboonduangjit, P.
    Paisangittisakul, N.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [3] Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam
    Yani, Sitti
    Dirgayussa, I. Gde Eka
    Rhani, Mohamad Fahdillah
    Soh, Roger C. X.
    Haryanto, Freddy
    Arif, Idam
    [J]. SMART SCIENCE, 2016, 4 (02): : 87 - 94
  • [4] Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations
    Wang, Lilie L. W.
    Beddar, Sam
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1596 - 1599
  • [5] An estimation of relative output factors of 6 MV photon beam using Monte Carlo simulation
    Saprangsi, W.
    Phaisangittisakul, N.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2416 - 2416
  • [6] Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code
    Sangeetha, S.
    Sureka, C. S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 63 - 75
  • [7] Optimisation of variance reduction techniques in EGSnrc Monte Carlo for a 6 MV photon beam of an Elekta Synergy linear accelerator
    Almatani, Turki
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2021, 33 (04)
  • [8] Analysis of characteristics and validation of 6 MV photon beam produced by Elekta Synergy linear accelerator using EGSnrc Monte Carlo code
    Gundem, Esin
    Dirican, Bahar
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 184
  • [9] Improvement of small-field electron beam dosimetry using Monte Carlo simulation
    Ma, CM
    Mok, E
    Kapur, A
    Findley, D
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 159 - 162
  • [10] Monte carlo model and output factors of elekta Infinity™ 6 and 10 MV photon beam
    Yani, Sitti
    Budiansah, Indra
    Rhani, Mohamad Fahdillah
    Haryanto, Freddy
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 470 - 478