Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam

被引:8
|
作者
Yani, Sitti [1 ,2 ]
Dirgayussa, I. Gde Eka [3 ]
Rhani, Mohamad Fahdillah [4 ]
Soh, Roger C. X. [5 ]
Haryanto, Freddy [1 ]
Arif, Idam [1 ]
机构
[1] Inst Teknol Bandung, Fac Math & Nat Sci, Dept Phys, Bandung, Indonesia
[2] Akad Kebidanan Pelita Ibu Kendari, Fac Midwifery, Kendari, Indonesia
[3] Inst Teknol Del, Fac Engn, Toba Samosir, Indonesia
[4] Natl Univ Canc Inst Singapore, Dept Radiat Oncol, Singapore, Singapore
[5] Nanyang Technol Univ, Sch Phys & Math Sci, Singapore 639798, Singapore
来源
SMART SCIENCE | 2016年 / 4卷 / 02期
关键词
Monte Carlo; photon beam; small field; electron contamination; output factors;
D O I
10.1080/23080477.2016.1195609
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study was to investigate the characteristics of electron contamination and Output Factors (OFs) from Varian Trilogy Clinac iX 6 MV photon beam at small field sizes. EGSnrc Monte Carlo (MC) code system was used to model the photon beam for this Linear Accelerator (Linac) head and analyze the electron contamination and OFs from this treatment head. The electron contamination was analyzed for field sizes of 1x1, 2x2, 3x3, 4x4, and 5x5cm(2). The number of electron contamination increases with increasing field sizes, but the maximum energy of the electron contamination stays constant (at around 1.87MeV for each field size). The contaminants contribute to the dose at the surface of the water phantom (1-5cm from the surface) for field size 4x4 and 5x5cm(2) and this dose decreases with depth. The OFs are simulated by EGSnrc code system and have a good agreement with measurement (deviation 3.45, 1.76, and 0.86 for field of 2, 3 and 4, respectively). This study presented that MC methods have great potential to accurately predict the electron contamination and OFs for 6 MV photon beam.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 50 条
  • [1] Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo
    Chuah, K. W.
    Aziz, Abdul M. Z.
    Jayamani, J.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 301 - 308
  • [2] An estimation of relative output factors of 6 MV photon beam using Monte Carlo simulation
    Saprangsi, W.
    Phaisangittisakul, N.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2416 - 2416
  • [3] Monte carlo model and output factors of elekta Infinity™ 6 and 10 MV photon beam
    Yani, Sitti
    Budiansah, Indra
    Rhani, Mohamad Fahdillah
    Haryanto, Freddy
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 470 - 478
  • [4] Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam
    Allahverdi, M.
    Zabihzadeh, M.
    Ay, M. R.
    Mahdavi, S. R.
    Shahriari, M.
    Mesbahi, A.
    Alijanzadeh, H.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2011, 9 (01): : 15 - 28
  • [5] Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
    Yani, S.
    Rhani, M. F.
    Soh, R. C. X.
    Haryanto, F.
    Arif, I.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 275 - +
  • [6] A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam
    Mesbahi, Asghar
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 55 - 60
  • [7] Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study
    Benmakhlouf, Hamza
    Sempau, Josep
    Andreo, Pedro
    [J]. MEDICAL PHYSICS, 2014, 41 (04)
  • [8] A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field
    Kirkby, C.
    Field, C.
    MacKenzie, M.
    Syme, A.
    Fallone, B. G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12): : 3563 - 3578
  • [9] Out-of-field beam characteristics of a 6 MV photon beam: Results of a Monte Carlo study
    Atarod, M.
    Shokrani, P.
    Azarnoosh, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2013, 72 : 182 - 194
  • [10] Monte Carlo calculated output correction factors for nine small field detectors in Varian Clinac iX 6 MV photon beams
    Benmakhlouf, H.
    Sempau, J.
    Andreo, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S201 - S202