Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

被引:33
|
作者
Wang, Lilie L. W. [1 ]
Beddar, Sam [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
plastic scintillation detectors; small-field photon beams; Monte Carlo simulations; CERENKOV RADIATION; NONSTANDARD FIELDS; DOSIMETRY; ENERGY; ELECTRON; SYSTEM;
D O I
10.1118/1.3554644
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10 x 10 down to 0.5 x 0.5 cm(2) for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5 x 0.5 cm(2) photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10 x 10 to 0.5 x 0.5 cm(2), while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3554644]
引用
收藏
页码:1596 / 1599
页数:4
相关论文
共 50 条
  • [1] Study of Response of Plastic Scintillation Detectors in Small Field 6 MV Photon Beams
    Wang, L.
    Beddar, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [2] Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams
    Wang, Lille L. W.
    Klein, David
    Beddar, A. Sam
    MEDICAL PHYSICS, 2010, 37 (10) : 5279 - 5286
  • [3] Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo
    Chuah, K. W.
    Aziz, Abdul M. Z.
    Jayamani, J.
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 301 - 308
  • [4] Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study
    Benmakhlouf, Hamza
    Sempau, Josep
    Andreo, Pedro
    MEDICAL PHYSICS, 2014, 41 (04)
  • [5] Monte Carlo Simulations of Cherenkov Photons on Plastic Scintillation Dosimeters Response to Megavoltage Photon Beams in Magnetic Fields
    Cervantes-Espinosa, Y.
    Lambert-Girard, S.
    Therriault-Proulx, F.
    Billas, I.
    Archambault, L.
    Beaulieu, L.
    MEDICAL PHYSICS, 2024, 51 (09) : 6574 - 6575
  • [6] Monte Carlo calculated output correction factors for nine small field detectors in Varian Clinac iX 6 MV photon beams
    Benmakhlouf, H.
    Sempau, J.
    Andreo, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S201 - S202
  • [7] On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry
    Andreo, Pedro
    Palmans, Hugo
    Marteinsdottir, Maria
    Benmakhlouf, Hamza
    Carlsson-Tedgren, Asa
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : L1 - L10
  • [8] Small-field dosimetry with multiple detectors and Monte Carlo calculations
    Parker, B
    Shin, A
    Liu, H
    MEDICAL PHYSICS, 2002, 29 (06) : 1372 - 1372
  • [9] Directional Dependence of the Response of Plastic Scintillation Detectors in Photon Beams
    Wang, L.
    Klein, D.
    Beddar, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Monte-Carlo determination of output correction factors for four detectors in small MV photon beams
    Valdes Santurio, G.
    Alfonso Laguardia, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S698 - S698