Increased Femoral Head Offset is Associated With Elevated Metal Ions in Asymptomatic Patients With Metal-on-Polyethylene Total Hip Arthroplasty

被引:19
|
作者
Martin, John R. [1 ]
Camp, Christopher L. [1 ]
Wyles, Cody C. [1 ]
Taunton, Michael J. [1 ]
Trousdale, Robert T. [1 ]
Lewallen, David G. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 12期
关键词
total hip arthroplasty; metal ions; cobalt; chrome; head size; offset; NECK TAPER; CORROSION; TRUNNIONS;
D O I
10.1016/j.arth.2016.05.047
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Predisposing factors for trunnionosis and elevated metal ion levels in metal-on-polyethylene (MOP) total hip arthroplasty (THA) are currently unknown. Methods: This retrospective cohort study enrolled 80 consecutive patients (43 males) with an asymptomatic MOP THA at 2- to 5-year follow-up and no other metal implants. Serum cobalt (Co) and chromium (Cr) levels were collected at the time of enrollment, and retrospective review was performed regarding demographic, implant, and surgical characteristics. Mean age at the time of surgery was 65.7 years (range 35.6-85.9 years), and mean postoperative follow-up was 28.7 months (range 24.4-58.9 months). Results: Femoral head offset was the only evaluated factor shown to increase serum Co ion levels above baseline within the cohort. Mean difference in Co level for high and low offset implants was 0.58 ppb (95% confidence interval [CI] = 0.05-1.11 ppb; P = .03). Mean difference in Cr level for high and low offset implants was 0.19 ppb (95% CI = -0.23 to 0.60 ppb; P = .37). Mean difference in Co level for small and large femoral heads was 0.20 ppb (95% CI = -0.41 to 0.81 ppb; P = .59). Mean difference in Cr level for small and large femoral heads was 0.28 ppb (95% CI = -0.18 to 0.74 ppb; P = .06). Age, gender, Harris Hip Score, and implant duration were not associated with changes in metal ion levels. Conclusion: Femoral head offset appears to be an important source of elevated metal ion levels in MOP THA. Further studies will be needed to understand if increasing femoral head offset is associated with subsequent adverse local tissue reactions. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2814 / 2818
页数:5
相关论文
共 50 条
  • [1] Pseudotumor Associated With Metal-on-Polyethylene Total Hip Arthroplasty
    Scully, Cpt William F.
    Teeny, Steven M.
    ORTHOPEDICS, 2013, 36 (05) : E666 - E670
  • [2] Material loss at the femoral head taper A COMPARISON STUDY OF THE EXETER METAL-ON-POLYETHYLENE AND CONTEMPORARY METAL-ON-METAL TOTAL HIP ARTHROPLASTY
    Langton, D. J.
    Wells, S. R.
    Joyce, T. J.
    Bowsher, J. G.
    Deehan, D.
    Green, S.
    Nargol, A. V. F.
    Holland, J. P.
    BONE & JOINT JOURNAL, 2018, 100B (10): : 1310 - 1319
  • [3] Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty
    Naudie, D
    Roeder, CP
    Parvizi, J
    Berry, DJ
    Eggli, S
    Busato, A
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 35 - 41
  • [4] Comparative Effectiveness of Metal-On-Metal and Metal-On-Polyethylene Bearings in Medicare Total Hip Arthroplasty Patients
    Bozic, Kevin J.
    Lau, Edmund C.
    Ong, Kevin L.
    Vail, Thomas P.
    Rubash, Harry E.
    Berry, Daniel J.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 37 - 40
  • [5] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [6] The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    MacAuliffe, John
    Peng, Yun
    Arauz, Paul
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2631 - 2635
  • [7] In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    Komistek, RD
    Dennis, DA
    Ochoa, JA
    Haas, BD
    Hammill, C
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10): : 1836 - 1841
  • [8] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2574 - 2579
  • [9] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 2279 - 2286
  • [10] Ten years on: increased metal ion levels in a cohort of patients who underwent uncemented metal-on-polyethylene total hip arthroplasty
    Dover, C.
    Kuiper, J. H.
    Craig, P.
    Shaylor, P.
    BONE & JOINT JOURNAL, 2020, 102B (07): : 832 - 837