Increased Femoral Head Offset is Associated With Elevated Metal Ions in Asymptomatic Patients With Metal-on-Polyethylene Total Hip Arthroplasty

被引:19
|
作者
Martin, John R. [1 ]
Camp, Christopher L. [1 ]
Wyles, Cody C. [1 ]
Taunton, Michael J. [1 ]
Trousdale, Robert T. [1 ]
Lewallen, David G. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 12期
关键词
total hip arthroplasty; metal ions; cobalt; chrome; head size; offset; NECK TAPER; CORROSION; TRUNNIONS;
D O I
10.1016/j.arth.2016.05.047
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Predisposing factors for trunnionosis and elevated metal ion levels in metal-on-polyethylene (MOP) total hip arthroplasty (THA) are currently unknown. Methods: This retrospective cohort study enrolled 80 consecutive patients (43 males) with an asymptomatic MOP THA at 2- to 5-year follow-up and no other metal implants. Serum cobalt (Co) and chromium (Cr) levels were collected at the time of enrollment, and retrospective review was performed regarding demographic, implant, and surgical characteristics. Mean age at the time of surgery was 65.7 years (range 35.6-85.9 years), and mean postoperative follow-up was 28.7 months (range 24.4-58.9 months). Results: Femoral head offset was the only evaluated factor shown to increase serum Co ion levels above baseline within the cohort. Mean difference in Co level for high and low offset implants was 0.58 ppb (95% confidence interval [CI] = 0.05-1.11 ppb; P = .03). Mean difference in Cr level for high and low offset implants was 0.19 ppb (95% CI = -0.23 to 0.60 ppb; P = .37). Mean difference in Co level for small and large femoral heads was 0.20 ppb (95% CI = -0.41 to 0.81 ppb; P = .59). Mean difference in Cr level for small and large femoral heads was 0.28 ppb (95% CI = -0.18 to 0.74 ppb; P = .06). Age, gender, Harris Hip Score, and implant duration were not associated with changes in metal ion levels. Conclusion: Femoral head offset appears to be an important source of elevated metal ion levels in MOP THA. Further studies will be needed to understand if increasing femoral head offset is associated with subsequent adverse local tissue reactions. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2814 / 2818
页数:5
相关论文
共 50 条
  • [21] Metal-on-polyethylene is not an option after the fracture of a ceramic component of a total hip arthroplasty
    Fernandez-Valencia, Jenaro A.
    HIP INTERNATIONAL, 2016, 26 (06) : E56 - E56
  • [22] Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results
    Zijlstra, Wierd P.
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    Zee, Mark J. M.
    Bulstra, Sjoerd K.
    van Raay, Jos J. A. M.
    HIP INTERNATIONAL, 2014, 24 (02) : 136 - 143
  • [23] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Qu, Xinhua
    Huang, Xiaolu
    Dai, Kerong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1573 - 1583
  • [24] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Xinhua Qu
    Xiaolu Huang
    Kerong Dai
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1573 - 1583
  • [25] Blood metal ions after hybrid metal-on-polyethylene Exeter−Trident total hip replacement
    Singh R.
    Manoharan G.
    Craig P.
    Collier S.
    Shaylor P.
    Sinha A.
    Journal of Orthopaedics and Traumatology, 2016, 17 (2) : 149 - 153
  • [26] Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination
    Damie, F
    Favard, L
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (03): : 241 - 248
  • [27] Femoral head wear and metallosis caused by damaged titanium porous coating after primary metal-on-polyethylene total hip arthroplasty: a case report
    Delimar, Domagoj
    Bohacek, Ivan
    Dimnjakovic, Damjan
    Viderscak, Dalibor
    Schauperl, Zdravko
    CROATIAN MEDICAL JOURNAL, 2018, 59 (05) : 253 - 257
  • [28] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Eoghan Pomeroy
    Fergal Macnamara
    Evelyn Murphy
    Niall McGoldrick
    Anant Mahapatra
    Nasir Awan
    Irish Journal of Medical Science (1971 -), 2019, 188 : 149 - 153
  • [29] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Pomeroy, Eoghan
    Macnamara, Fergal
    Murphy, Evelyn
    McGoldrick, Niall
    Mahapatra, Anant
    Awan, Nasir
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 149 - 153
  • [30] Clinically insignificant trunnionosis in large- diameter metal-on-polyethylene total hip arthroplasty
    Hothi, H. S.
    Kendoff, D.
    Lausmann, C.
    Henckel, J.
    Gehrke, T.
    Skinner, J.
    Hart, A.
    BONE & JOINT RESEARCH, 2017, 6 (01): : 52 - 56