In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty

被引:89
|
作者
Komistek, RD [1 ]
Dennis, DA [1 ]
Ochoa, JA [1 ]
Haas, BD [1 ]
Hammill, C [1 ]
机构
[1] Rocky Mtn Musculoskeletal Res Lab, Denver, CO 80222 USA
来源
关键词
D O I
10.2106/00004623-200210000-00015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Twenty subjects were analyzed in vivo with use of video fluoroscopy to determine if the femoral head separates from the acetabular component during normal gait and to determine if the amount of separation differs between metal-on-metal and meta I-on-polyethylene total hip prostheses. Methods: Ten subjects had been treated with a metal-on-metal total hip arthroplasty and ten, with a meta I-on-polyethylene total hip arthroplasty. All of the prostheses were implanted by the same surgeon utilizing the same surgical technique, and all were judged to be clinically successful (a Harris hip score of >90 points). Each subject walked with a normal gait on a level treadmill while under fluoroscopic surveillance. The two-dimensional fluoroscopic videotapes were then converted into three-dimensional images with use of a computer-automated model-fitting technique. Each implant was analyzed at various flexion angles to assess the amount of femoral head sliding. Results: No femoral head sliding was observed in the subjects with a metal-on-metal implant, whereas all ten subjects with a meta I-on-polyethylene implant had sliding that was greater than our threshold value of 0.75 mm. The average amount of femoral head sliding in these subjects was 2.0 mm, and the sliding was observed during the swing phase of gait. The sliding was typically seen medially while the femoral head remained in contact with the acetabular component superolaterally. Conclusions: Femoral head sliding commonly occurred following traditional meta I-on-polyethylene total hip arthroplasty but not after metal-on-metal arthroplasty. These kinematic data may be of value in future hip-simulation studies to better duplicate wear patterns observed in retrieval analyses, assist in the understanding of the lubrication and wear rates of metal-on-metal designs, and facilitate designing of prosthetic components that minimize wear and optimize hip kinematics.
引用
收藏
页码:1836 / 1841
页数:6
相关论文
共 50 条
  • [1] Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty
    Naudie, D
    Roeder, CP
    Parvizi, J
    Berry, DJ
    Eggli, S
    Busato, A
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 35 - 41
  • [2] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    [J]. BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [3] Comparison of Complications Following Revision of Metal-on-Metal Versus Metal-on-Polyethylene Total Hip Arthroplasty
    Nishio, Shoji
    Fukunishi, Shigeo
    Yoshiya, Shinichi
    Sing, David C.
    Hansen, Erik N.
    Vail, Thomas P.
    [J]. ORTHOPEDICS, 2017, 40 (01) : E164 - E169
  • [4] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2574 - 2579
  • [5] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 2279 - 2286
  • [6] Comparative Effectiveness of Metal-On-Metal and Metal-On-Polyethylene Bearings in Medicare Total Hip Arthroplasty Patients
    Bozic, Kevin J.
    Lau, Edmund C.
    Ong, Kevin L.
    Vail, Thomas P.
    Rubash, Harry E.
    Berry, Daniel J.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 37 - 40
  • [7] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Qu, Xinhua
    Huang, Xiaolu
    Dai, Kerong
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1573 - 1583
  • [8] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Xinhua Qu
    Xiaolu Huang
    Kerong Dai
    [J]. Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1573 - 1583
  • [9] Material loss at the femoral head taper A COMPARISON STUDY OF THE EXETER METAL-ON-POLYETHYLENE AND CONTEMPORARY METAL-ON-METAL TOTAL HIP ARTHROPLASTY
    Langton, D. J.
    Wells, S. R.
    Joyce, T. J.
    Bowsher, J. G.
    Deehan, D.
    Green, S.
    Nargol, A. V. F.
    Holland, J. P.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (10): : 1310 - 1319
  • [10] Metal-on-Metal Total Hip Arthroplasty
    Kim, Raymond H.
    Dennis, Douglas A.
    Carothers, Joshua T.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 44 - 46