In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty

被引:89
|
作者
Komistek, RD [1 ]
Dennis, DA [1 ]
Ochoa, JA [1 ]
Haas, BD [1 ]
Hammill, C [1 ]
机构
[1] Rocky Mtn Musculoskeletal Res Lab, Denver, CO 80222 USA
来源
关键词
D O I
10.2106/00004623-200210000-00015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Twenty subjects were analyzed in vivo with use of video fluoroscopy to determine if the femoral head separates from the acetabular component during normal gait and to determine if the amount of separation differs between metal-on-metal and meta I-on-polyethylene total hip prostheses. Methods: Ten subjects had been treated with a metal-on-metal total hip arthroplasty and ten, with a meta I-on-polyethylene total hip arthroplasty. All of the prostheses were implanted by the same surgeon utilizing the same surgical technique, and all were judged to be clinically successful (a Harris hip score of >90 points). Each subject walked with a normal gait on a level treadmill while under fluoroscopic surveillance. The two-dimensional fluoroscopic videotapes were then converted into three-dimensional images with use of a computer-automated model-fitting technique. Each implant was analyzed at various flexion angles to assess the amount of femoral head sliding. Results: No femoral head sliding was observed in the subjects with a metal-on-metal implant, whereas all ten subjects with a meta I-on-polyethylene implant had sliding that was greater than our threshold value of 0.75 mm. The average amount of femoral head sliding in these subjects was 2.0 mm, and the sliding was observed during the swing phase of gait. The sliding was typically seen medially while the femoral head remained in contact with the acetabular component superolaterally. Conclusions: Femoral head sliding commonly occurred following traditional meta I-on-polyethylene total hip arthroplasty but not after metal-on-metal arthroplasty. These kinematic data may be of value in future hip-simulation studies to better duplicate wear patterns observed in retrieval analyses, assist in the understanding of the lubrication and wear rates of metal-on-metal designs, and facilitate designing of prosthetic components that minimize wear and optimize hip kinematics.
引用
收藏
页码:1836 / 1841
页数:6
相关论文
共 50 条
  • [21] Metal-on-metal articulation in total hip arthroplasty
    Marchetti, PG
    Binazzi, R
    Vaccari, V
    Manca, A
    Rossi, R
    Campagna, A
    Magnani, M
    Baldarelli, M
    Pasini, E
    BIOCERAMICS, 2000, 192-1 : 975 - 977
  • [22] The rationale for metal-on-metal total hip arthroplasty
    Cuckler, JM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 132 - 136
  • [23] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Wierd P Zijlstra
    Nanne Bos
    Jos JAM van Raaij
    BMC Musculoskeletal Disorders, 9
  • [24] Painful metal-on-metal total hip arthroplasty
    Shahrdar, C
    Campbell, P
    Mirra, J
    Dorr, LD
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02): : 289 - 293
  • [25] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Zijlstra, Wierd P.
    Bos, Nanne
    van Raaij, Jos J. A. M.
    BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)
  • [26] Metal-on-Metal vs Metal-on-Improved Polyethylene Bearings in Total Hip Arthroplasty
    Molli, Ryan G.
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Adams, Joanne B.
    Sneller, Michael A.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06): : 8 - 13
  • [27] Metal ion concentrations and semen quality in patients undergoing hip arthroplasty: A prospective comparison between metal-on-metal and metal-on-polyethylene implants
    Chen, Szu-Yuan
    Chang, Chih-Hsiang
    Hu, Chih-Chien
    Chen, Chun-Chieh
    Chang, Yu-Han
    Hsieh, Pang-Hsin
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (03) : 544 - 551
  • [28] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S284 - S288
  • [29] Metal-on-polyethylene is not an option after the fracture of a ceramic component of a total hip arthroplasty
    Fernandez-Valencia, Jenaro A.
    HIP INTERNATIONAL, 2016, 26 (06) : E56 - E56
  • [30] The Prevalence of Groin Pain After Metal-on-Metal Total Hip Arthroplasty and Total Hip Resurfacing
    Bartelt, Robert B.
    Yuan, Brandon J.
    Trousdale, Robert T.
    Sierra, Rafael J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2346 - 2356