Accuracy of the Minicardio system for heart rate variability analysis compared to ECG

被引:0
|
作者
Cassirame, J. [1 ]
Stuckey, M. I. [2 ,3 ]
Sheppard, F.
Tordi, N. [4 ,5 ]
机构
[1] Univ Franche Comte, Univ Hosp Besancon, EA Physiopathol Cardiovasc & Prevent 3920, F-25030 Besancon, France
[2] Univ Western Ontario, Dept Kinesiol, London, ON, Canada
[3] Lawson Hlth Res Inst, London, ON, Canada
[4] Univ Hosp Besancon, INSERM CIT808, Ctr Invest Clin Innovat Technol, Besancon, France
[5] Univ Franche Comte, EA Fonct & Dysfonct Epitheliale 4267, F-25030 Besancon, France
来源
关键词
Heart rate; Heart function tests; Resistance training; R-R INTERVALS; POLAR S810; VENTILATORY THRESHOLDS; RATE DYNAMICS; RATE MONITOR; VALIDITY; TIME;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Aim. The purpose of this investigation was twofold: firstly, to assess the accuracy of heart rate (HR) measurements from Minicardio compared to a standard electrocardiogram (ECG) and secondly, to compare the heart rate variability analysis carried out for each set of data. Methods. Fifteen young participants volunteered for this study and were instrumented for the simultaneous recording of HR via ECG and Minicardio. HR was recorded continuously during 10 minutes of supine rest and 2 consecutive exercise bouts (target HR at 130 bpm and 150 bpm). R-R intervals were determined in order to compare the number and type of artifacts in each data set. The device were then compared by determining the type and number of artifacts, correlations between HRV analysis parameters and Bland-Altman limits of agreement. Results. No artifact was produced from ECG. With Minicardio, no artifact was produced during supine rest, during exercise there were 2 type 1 (long R-R interval) and 7 type 2 artifacts (short R-R interval). For time domain analysis, Pearson coefficients were 1 for SDNN and mean R-R interval and 0.99 for RMSSD and pNN50. For frequency domain analysis, Pearson coefficients were 0.99 for high frequency and low frequency power, and 0.99 for Poincare plots SD1 and SD2. Limits of agreement from Bland-Altman analysis showed an excellent agreement between all devices Conclusion. The similarity between ECG and Minicardio encourages us to use Minicardio as a portable HR recorder for subjects at rest and during moderate cycling exercise.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 50 条
  • [31] Analysis and Comparison of Heart Rate Variability Signals Derived from PPG and ECG Sensors
    Krolak, Aleksandra
    Pilecka, Edyta
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING - CURRENT TRENDS AND CHALLENGES, 2022, 293 : 9 - 16
  • [32] Fuzzification of the Analysis of Heart Rate Variability Using ECG in Time, Frequency and Statistical Domains
    Sadiq, Ismail
    Khan, Shoab Ahmad
    2010 SECOND INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND APPLICATIONS: ICCEA 2010, PROCEEDINGS, VOL 1, 2010, : 481 - 485
  • [33] Response of arrhythmia to spinal manipulation: Monitoring by ECG with analysis of heart-rate variability
    Budgell, BS
    Igarashi, Y
    JNMS-JOURNAL OF THE NEUROMUSCULOSKELETAL SYSTEM, 2001, 9 (03): : 97 - 102
  • [34] Stress Index Calculation and Analysis based on Heart Rate Variability of ECG Signal with Arrhythmia
    Sahoo, Tanmay Kumar
    Mahapatra, Ashutos
    Ruban, Nersisson
    2019 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2019,
  • [35] A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability
    Sarhaddi, Fatemeh
    Kazemi, Kianoosh
    Azimi, Iman
    Cao, Rui
    Niela-Vilen, Hannakaisa
    Axelin, Anna
    Liljeberg, Pasi
    Rahmani, Amir M.
    PLOS ONE, 2022, 17 (12):
  • [36] Comparison of finger plethysmograph to ECG in the measurement of heart rate variability
    Giardino, ND
    Lehrer, PM
    Edelberg, R
    PSYCHOPHYSIOLOGY, 2002, 39 (02) : 246 - 253
  • [37] A Flexible Dry ECG Patch for Heart Rate Variability Monitoring
    Ahmad, Meraj
    Malik, Shahid
    Somappa, Laxmeesha
    Sonkusale, Sameer
    Baghini, Maryam Shojaei
    2020 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS (IEEE FLEPS 2020), 2020,
  • [38] A comparison of finger plethysmograph to ECG in the measurement of heart rate variability
    Giardino, ND
    Lehrer, PM
    Edelberg, R
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 1998, 23 (02) : 114 - 115
  • [39] A comparison of finger plethysmograph to ECG in the measurement of heart rate variability
    Giardino, ND
    Lehrer, PM
    Edelberg, R
    FROM FANTASY TO REALITY - CREATING THE FUTURE OF APPLIED PSYCHOPHYSIOLOGY - PROCEEDINGS, 1998, : 17 - 19
  • [40] Explainable artificial intelligence for heart rate variability in ECG signal
    Sanjana, K.
    Sowmya, V
    Gopalakrishnan, E. A.
    Soman, K. P.
    HEALTHCARE TECHNOLOGY LETTERS, 2020, 7 (06) : 146 - 154