Analysis and Comparison of Heart Rate Variability Signals Derived from PPG and ECG Sensors

被引:2
|
作者
Krolak, Aleksandra [1 ]
Pilecka, Edyta [1 ]
机构
[1] Lodz Univ Technol, Inst Elect, Lodz, Poland
关键词
ECG; PPG; HRV; PRY; HRV parameters;
D O I
10.1007/978-3-030-83704-4_2
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
One of the methods of diagnosis and prevention of cardiovascular diseases is monitoring and analysis of heart rate variability (HRV). However, in order to accurately detect the RR intervals, the ECG signal must be acquired. The advances in optical sensors made photoplethysmography (PPG) to be considered as an alternative for heartbeat interval measurements as it is more convenient. The aim of this study is to compare the HRV signals calculated from ECG and PPG measurements based on the data from two Physionet datasets and assess the reliability and accuracy of time-domain, frequency-domain and nonlinear HRV parameters derived from the ECG and PPG signals. The results achieved suggest that the PRV can be used as an alternative for HRV analysis in static measurements, with significant correlation coefficient values above 98% for nonlinear, time and frequency features. In the dynamic measurements, performed during sports activities, especially nonlinear and frequency-domain parameters derived from PPG signals should be used with caution, as in some cases the correlation was inverse.
引用
下载
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [1] Comparative Heart Rate Variability Analysis of ECG, Holter and PPG Signals
    Georgieva-Tsaneva, Galya N.
    Gospodinova, Evgeniya
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2021, 12 (12) : 464 - 470
  • [2] A Robust Algorithm for Derivation of Heart Rate Variability Spectra from ECG and PPG Signals
    Verma, Ajay
    Cabrera, Sergio
    Mayorga, Allan
    Nazeran, Homer
    29TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE (SBEC 2013), 2013, : 35 - 36
  • [3] Heart rate variability and heart rate monitoring of nurses using PPG and ECG signals during working condition: A pilot study
    Li, Xinxia
    Hu, Chenghong
    Meng, Airong
    Guo, Yanmei
    Chen, Yang
    Dang, Rongqing
    HEALTH SCIENCE REPORTS, 2022, 5 (01)
  • [4] System to ECG Signals Variability Analysis: Heart Rate Variability and QT Interval Variability
    Petry, D.
    Palodeto, V.
    Suzuki, D. O. H.
    Marques, J. L. B.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1160 - +
  • [5] Correlation Analysis of Heart Rate Variability between PPG and ECG for Wearable Devices in Different Postures
    Hsiao, Chun-Chieh
    Hsu, Fang-Wei
    Lee, Ren-Guey
    Lin, Robert
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 2957 - 2962
  • [6] Comparing heart rate variability derived from ECG and BP waveforms
    McKinley, PS
    Myers, MM
    Bagiella, E
    Shapiro, PA
    Sloan, RP
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 176 - 176
  • [7] The PPG Physiological Signal for Heart Rate Variability Analysis
    Jong, Gwo-Jia
    Aripriharta
    Horng, Gwo-Jiun
    WIRELESS PERSONAL COMMUNICATIONS, 2017, 97 (04) : 5229 - 5276
  • [8] The PPG Physiological Signal for Heart Rate Variability Analysis
    Gwo-Jia Jong
    Gwo-Jiun Aripriharta
    Wireless Personal Communications, 2017, 97 : 5229 - 5276
  • [9] Extraction of Fetal ECG from Abdominal ECG and Heart Rate Variability Analysis
    Lamesgin, Gizeaddis
    Kassaw, Yonas
    Assefa, Dawit
    AFRO-EUROPEAN CONFERENCE FOR INDUSTRIAL ADVANCEMENT, AECIA 2014, 2015, 334 : 65 - 76
  • [10] Comparison of Respiratory Rates Derived from Heart Rate Variability, ECG Amplitude, and Nasal/Oral Airflow
    Cysarz, Dirk
    Zerm, Roland
    Bettermann, Henrik
    Fruehwirth, Matthias
    Moser, Maximilian
    Kroez, Matthias
    ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (12) : 2085 - 2094