Analysis and Comparison of Heart Rate Variability Signals Derived from PPG and ECG Sensors

被引:2
|
作者
Krolak, Aleksandra [1 ]
Pilecka, Edyta [1 ]
机构
[1] Lodz Univ Technol, Inst Elect, Lodz, Poland
关键词
ECG; PPG; HRV; PRY; HRV parameters;
D O I
10.1007/978-3-030-83704-4_2
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
One of the methods of diagnosis and prevention of cardiovascular diseases is monitoring and analysis of heart rate variability (HRV). However, in order to accurately detect the RR intervals, the ECG signal must be acquired. The advances in optical sensors made photoplethysmography (PPG) to be considered as an alternative for heartbeat interval measurements as it is more convenient. The aim of this study is to compare the HRV signals calculated from ECG and PPG measurements based on the data from two Physionet datasets and assess the reliability and accuracy of time-domain, frequency-domain and nonlinear HRV parameters derived from the ECG and PPG signals. The results achieved suggest that the PRV can be used as an alternative for HRV analysis in static measurements, with significant correlation coefficient values above 98% for nonlinear, time and frequency features. In the dynamic measurements, performed during sports activities, especially nonlinear and frequency-domain parameters derived from PPG signals should be used with caution, as in some cases the correlation was inverse.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [41] Analysis of human PPG, ECG and EEG signals by eigenvector methods
    Ubeyli, Elif Derya
    Cvetkovic, Dean
    Cosic, Irena
    DIGITAL SIGNAL PROCESSING, 2010, 20 (03) : 956 - 963
  • [42] Classification of Acute Stress using Linear and Non-Linear Heart Rate Variability Analysis Derived from Sternal ECG
    Tanev, George
    Saadi, Dorthe B.
    Hoppe, Karsten
    Sorensen, Helge B. D.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3386 - 3389
  • [43] Heart Rate Variability and Wavelet-based Studies on ECG Signals from Smokers and Non-smokers
    Pal K.
    Goel R.
    Champaty B.
    Samantray S.
    Tibarewala D.N.
    Journal of The Institution of Engineers (India): Series B, 2013, 94 (4) : 275 - 283
  • [44] A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
    Lu, G.
    Yang, F.
    Taylor, J.A.
    Stein, J.F.
    Journal of Medical Engineering and Technology, 2009, 33 (08): : 634 - 641
  • [45] Ambulatory ECG and analysis of heart rate variability in Parkinson's disease
    Haapaniemi, TH
    Pursiainen, V
    Korpelainen, JT
    Huikuri, HV
    Sotaniemi, KA
    Myllylä, VV
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2001, 70 (03): : 305 - 310
  • [46] Accuracy of the Minicardio system for heart rate variability analysis compared to ECG
    Cassirame, J.
    Stuckey, M. I.
    Sheppard, F.
    Tordi, N.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2013, 53 (03): : 248 - 254
  • [47] Influence of Undetected ECG R waves on the Heart Rate Variability Analysis
    Naka, H.
    Tohara, T.
    Inoue, K.
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 3068 - 3072
  • [48] ECG system with heart rate variability application
    Naiyanetr, P
    Charoentong, P
    Charoensuk, W
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : B435 - B437
  • [49] High resolution ECG and heart rate variability
    Voss, A
    Wessel, N
    Dietz, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1622 - 1623
  • [50] Comparison of Heart Rate Variability Assessment During Exercise from Polar RS800 and ECG
    Hernando, David
    Garatachea, Nuria
    Casajus, Jose A.
    Bailon, Raquel
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44