Accuracy of the Minicardio system for heart rate variability analysis compared to ECG

被引:0
|
作者
Cassirame, J. [1 ]
Stuckey, M. I. [2 ,3 ]
Sheppard, F.
Tordi, N. [4 ,5 ]
机构
[1] Univ Franche Comte, Univ Hosp Besancon, EA Physiopathol Cardiovasc & Prevent 3920, F-25030 Besancon, France
[2] Univ Western Ontario, Dept Kinesiol, London, ON, Canada
[3] Lawson Hlth Res Inst, London, ON, Canada
[4] Univ Hosp Besancon, INSERM CIT808, Ctr Invest Clin Innovat Technol, Besancon, France
[5] Univ Franche Comte, EA Fonct & Dysfonct Epitheliale 4267, F-25030 Besancon, France
来源
关键词
Heart rate; Heart function tests; Resistance training; R-R INTERVALS; POLAR S810; VENTILATORY THRESHOLDS; RATE DYNAMICS; RATE MONITOR; VALIDITY; TIME;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Aim. The purpose of this investigation was twofold: firstly, to assess the accuracy of heart rate (HR) measurements from Minicardio compared to a standard electrocardiogram (ECG) and secondly, to compare the heart rate variability analysis carried out for each set of data. Methods. Fifteen young participants volunteered for this study and were instrumented for the simultaneous recording of HR via ECG and Minicardio. HR was recorded continuously during 10 minutes of supine rest and 2 consecutive exercise bouts (target HR at 130 bpm and 150 bpm). R-R intervals were determined in order to compare the number and type of artifacts in each data set. The device were then compared by determining the type and number of artifacts, correlations between HRV analysis parameters and Bland-Altman limits of agreement. Results. No artifact was produced from ECG. With Minicardio, no artifact was produced during supine rest, during exercise there were 2 type 1 (long R-R interval) and 7 type 2 artifacts (short R-R interval). For time domain analysis, Pearson coefficients were 1 for SDNN and mean R-R interval and 0.99 for RMSSD and pNN50. For frequency domain analysis, Pearson coefficients were 0.99 for high frequency and low frequency power, and 0.99 for Poincare plots SD1 and SD2. Limits of agreement from Bland-Altman analysis showed an excellent agreement between all devices Conclusion. The similarity between ECG and Minicardio encourages us to use Minicardio as a portable HR recorder for subjects at rest and during moderate cycling exercise.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 50 条
  • [21] Handheld ECG in analysis of arrhythmia and heart rate variability in children with Fontan circulation
    Dahlqvist, Jenny Alenius
    Karlsson, Marcus
    Wiklund, Urban
    Hornsten, Rolf
    Rydberg, Annika
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (03) : 374 - 382
  • [22] Sternal Pulse Rate Variability Compared with Heart Rate Variability on Healthy Subjects
    Chreiteh, Shadi S.
    Belhage, Bo
    Hoppe, Karsten
    Branebjerg, Jens
    Thomsen, Erik V.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3394 - 3397
  • [23] A new approach for analysis of heart rate variability and QT variability in long-term ECG recording
    Wu, Hau-Tieng
    Soliman, Elsayed Z.
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [24] A new approach for analysis of heart rate variability and QT variability in long-term ECG recording
    Hau-Tieng Wu
    Elsayed Z. Soliman
    BioMedical Engineering OnLine, 17
  • [25] PC based system for heart rate variability analysis
    Ali, K
    Taha, I
    Jacobson, M
    COMPUTERS AND THEIR APPLICATIONS, 2000, : 29 - 32
  • [26] CONSTRUCTING A HEART-RATE-VARIABILITY ANALYSIS SYSTEM
    JAFFE, RS
    FUNG, DL
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (01): : 45 - 58
  • [27] Heart Rate Variability Modulates Interoceptive Accuracy
    Lischke, Alexander
    Pahnke, Rike
    Mau-Moeller, Anett
    Weippert, Matthias
    FRONTIERS IN NEUROSCIENCE, 2021, 14
  • [28] Accuracy of heart rate measured by military-grade wearable ECG monitor compared with reference and commercial monitors
    Lindsey, Bryndan
    Hanley, C.
    Reider, L.
    Snyder, S.
    Zhou, Y.
    Bell, E.
    Shim, J.
    Hahn, J-o
    Vignos, M.
    Bar-Kochba, E.
    BMJ MILITARY HEALTH, 2023,
  • [29] Analysis of Heart Rate Variability in Normal and Diabetic ECG signals using Fragmentation Approach
    Navaneethakrishna, M.
    Manuskandan, S. R.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1112 - 1115
  • [30] Early and Later Post-Exercise Heart Rate Variability Analysis of ECG Signal
    Kumar, Prashant
    Das, Ashis Kumar
    Halder, Suman
    IEEE INDICON: 15TH IEEE INDIA COUNCIL INTERNATIONAL CONFERENCE, 2018,