Comparison of Less Invasive Stabilization System Plate and Retrograde Intramedullary Nail in the Fixation of Femoral Supracondylar Fractures in the Elderly: A Biomechanical Study

被引:17
|
作者
Du, Yu-ren [1 ]
Ma, Jian-xiong [2 ]
Wang, Shuo [3 ,4 ]
Sun, Lei [2 ]
Wang, Ying [2 ]
Lu, Bin [2 ]
Bai, Hao-hao [2 ]
Hu, Yong-cheng [3 ]
Ma, Xin-long [1 ,2 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Dept Orthopaed, Tianjin, Peoples R China
[2] Tianjin Hosp, Tianjin Inst Orthopaed, Tianjin 300050, Peoples R China
[3] Tianjin Hosp, Dept Orthopaed, Tianjin 300211, Peoples R China
[4] 464 Hosp Peoples Liberat Army, Dept Orthopaed, Tianjin, Peoples R China
关键词
Biomechanical testing; Comminuted femoral supracondylar fracture; Less invasive stabilization system plate; Retrograde intramedullary nail; DISTAL FEMUR FRACTURES; INTERNAL-FIXATION; LCP; EPIDEMIOLOGY; LISS;
D O I
10.1111/os.12449
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the biomechanical stabilities of less invasive stabilization system (LISS) plate and retrograde intramedullary nail (IMN) for the comminuted femoral supracondylar fracture fractures in the elderly. Methods Sixteen pairs of embalmed cadaver femurs were obtained to simulate a comminuted supracondylar femur fracture (AO/OTA33-A3) gap model. All left-side specimens were fixed with LISS plate, and retrograde IMN were applied to the right-side specimens. All specimens were tested in torsional, axial and cyclic load mode on an Instron testing machine. Results The mean torsional stiffness for LISS plate group was 34.1% greater than retrograde IMN group (2.90 vs. 1.91 Nm/degree, P = 0.002), but the mean axial stiffness was greater for the retrograde IMN (199.16 vs. 303.93 N/mm, P < 0.001). The total deformation of LISS plate caused by cyclic axial loading was greater than retrograde IMN (4.17 vs. 3.57 mm, P = 0.014). Significantly less mean irreversible deformation was detected in LISS plate than in retrograde IMN (1.64 vs. 1.69 mm, P = 0.699). Failure loads of the constructs were significantly different between the two groups (LISS plate: 2941 +/- 128 N; retrograde IMN: 4022 +/- 176 N, P < 0.001). Conclusion For comminuted femoral supracondylar fractures in the elderly, the tested instruments can both maintain sufficient biomechanical stabilities, but retrograde IMN is superior to LISS plate in deformation of fracture site.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [31] Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail
    Meyer, RW
    Plaxton, NA
    Postak, PD
    Gilmore, A
    Froimson, MI
    Greenwald, AS
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) : 398 - 404
  • [32] Supplemental Fixation of Supracondylar Distal Femur Fractures: A Biomechanical Comparison of Dual-Plate and Plate-Nail Constructs
    Wright, David J.
    DeSanto, Donald J.
    McGarry, Michelle H.
    Lee, Thay Q.
    Scolaro, John A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (08) : 434 - 440
  • [33] Biomechanical evaluation of intramedullary nail and bone plate for the fixation of distal metaphyseal fractures
    Nourisa, Jalil
    Rouhi, Gholamreza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 56 : 34 - 44
  • [34] Biomechanical Evaluation of Retrograde Intramedullary Stabilization for Femoral Fractures The Effect of Fracture Level
    Goodwin, Ryan
    Mahar, Andrew T.
    Oka, Richard
    Steinman, Suzanne
    Newton, Peter O.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (08) : 873 - 876
  • [35] Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability
    Basci, Onur
    Karakasli, Ahmet
    Kumtepe, Erdem
    Guran, Orta
    Havitcioglu, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (01): : 21 - 26
  • [36] Biomechanical comparison of intramedullary nail and blade plate fixation for tibiotalocalcaneal arthrodesis
    Alfahd, UA
    Roth, SE
    Stephen, D
    Whyne, CM
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) : 703 - 708
  • [37] Biomechanical Comparison of Intramedullary Fibular Nail Versus Plate and Screw Fixation
    Smith, George
    Mackenzie, Samuel Peter
    Wallace, Robert James
    Carter, Tom
    White, Timothy Oliver
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (12) : 1394 - 1399
  • [38] Biomechanical Comparison of Blade Plate and Intramedullary Nail Fixation for Tibiocalcaneal Arthrodesis
    Lee, Arthur T.
    Sundberg, Eric B.
    Lindsey, Derek P.
    Harris, Alex H. S.
    Chou, Loretta B.
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (02) : 164 - 171
  • [39] Numerical comparison of the intramedullary nail for the fixation of different proximal femoral fractures
    Chen, Yen-Nien
    Chang, Chih-Wei
    Su, Kuo-Chih
    Chang, Chia-Jung
    CLINICAL BIOMECHANICS, 2025, 122
  • [40] Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate
    Heiney, Jake P.
    Barnett, Michael D.
    Vrabec, Gregory A.
    Schoenfeld, Andrew J.
    Baji, Avinash
    Njus, Glen O.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02): : 443 - 449