Comparison of Less Invasive Stabilization System Plate and Retrograde Intramedullary Nail in the Fixation of Femoral Supracondylar Fractures in the Elderly: A Biomechanical Study

被引:17
|
作者
Du, Yu-ren [1 ]
Ma, Jian-xiong [2 ]
Wang, Shuo [3 ,4 ]
Sun, Lei [2 ]
Wang, Ying [2 ]
Lu, Bin [2 ]
Bai, Hao-hao [2 ]
Hu, Yong-cheng [3 ]
Ma, Xin-long [1 ,2 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Dept Orthopaed, Tianjin, Peoples R China
[2] Tianjin Hosp, Tianjin Inst Orthopaed, Tianjin 300050, Peoples R China
[3] Tianjin Hosp, Dept Orthopaed, Tianjin 300211, Peoples R China
[4] 464 Hosp Peoples Liberat Army, Dept Orthopaed, Tianjin, Peoples R China
关键词
Biomechanical testing; Comminuted femoral supracondylar fracture; Less invasive stabilization system plate; Retrograde intramedullary nail; DISTAL FEMUR FRACTURES; INTERNAL-FIXATION; LCP; EPIDEMIOLOGY; LISS;
D O I
10.1111/os.12449
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the biomechanical stabilities of less invasive stabilization system (LISS) plate and retrograde intramedullary nail (IMN) for the comminuted femoral supracondylar fracture fractures in the elderly. Methods Sixteen pairs of embalmed cadaver femurs were obtained to simulate a comminuted supracondylar femur fracture (AO/OTA33-A3) gap model. All left-side specimens were fixed with LISS plate, and retrograde IMN were applied to the right-side specimens. All specimens were tested in torsional, axial and cyclic load mode on an Instron testing machine. Results The mean torsional stiffness for LISS plate group was 34.1% greater than retrograde IMN group (2.90 vs. 1.91 Nm/degree, P = 0.002), but the mean axial stiffness was greater for the retrograde IMN (199.16 vs. 303.93 N/mm, P < 0.001). The total deformation of LISS plate caused by cyclic axial loading was greater than retrograde IMN (4.17 vs. 3.57 mm, P = 0.014). Significantly less mean irreversible deformation was detected in LISS plate than in retrograde IMN (1.64 vs. 1.69 mm, P = 0.699). Failure loads of the constructs were significantly different between the two groups (LISS plate: 2941 +/- 128 N; retrograde IMN: 4022 +/- 176 N, P < 0.001). Conclusion For comminuted femoral supracondylar fractures in the elderly, the tested instruments can both maintain sufficient biomechanical stabilities, but retrograde IMN is superior to LISS plate in deformation of fracture site.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [11] Retrograde interlocking nailing of distal femoral fractures with the supracondylar intramedullary nail
    Ostermann, PAW
    Hahn, MP
    Ekkernkamp, A
    David, A
    Muhr, G
    CHIRURG, 1996, 67 (11): : 1135 - 1140
  • [12] Less invasive stabilising system plate versus retrograde intramedullary nail for osteoporotic distal femoral fracture
    Garg, Bhavuk
    Malhotra, Rajesh
    Kumar, Vijay
    Kotwal, P. P.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (05): : 381 - 381
  • [13] Less invasive stabilising system plate versus retrograde intramedullary nail for osteoporotic distal femoral fracture
    Bhavuk Garg
    Rajesh Malhotra
    Vijay Kumar
    P. P. Kotwal
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 381 - 381
  • [14] Less-Invasive Stabilization of Rib Fractures by Intramedullary Fixation: A Biomechanical Evaluation
    Bottlang, Michael
    Helzel, Inga
    Long, William
    Fitzpatrick, Daniel
    Madey, Steven
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (05): : 1218 - 1224
  • [15] Less invasive stabilising system plate versus retrograde intramedullary nail for osteoporotic distal femoral fracture
    Mukherjee, Pavel
    Bovell, Christopher
    Davis, James
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (04): : 281 - 284
  • [16] Less invasive stabilising system plate versus retrograde intramedullary nail for osteoporotic distal femoral fracture
    Pavel Mukherjee
    Christopher Bovell
    James Davis
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 281 - 284
  • [17] RETROGRADE INTRAMEDULLARY INTERLOCKING NAIL: AN OPTIMAL TOOL FOR THE TREATMENT OF SUPRACONDYLAR FEMORAL FRACTURES
    Kamareddy, S. B.
    Bharadwaj, Sanjeevi
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (50): : 11798 - 11805
  • [18] Periprosthetic Supracondylar Femoral Fractures Above a Total Knee Replacement: Compatibility Guide for Fixation With a Retrograde Intramedullary Nail
    Thompson, Simon M.
    Lindisfarne, Edward A. O.
    Bradley, Neil
    Solan, Matthew
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1639 - 1641
  • [19] Biomechanical analysis of supracondylar femoral fractures fixed with modern retrograde intramedullary nails
    Hora, N
    Markel, DC
    Haynes, A
    Grimm, MJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) : 539 - 544
  • [20] MECHANICS OF RETROGRADE NAIL VERSUS PLATE FIXATION FOR SUPRACONDYLAR FEMUR FRACTURES
    FIROOZBAKHSH, K
    BEHZADI, K
    DECOSTER, TA
    MONEIM, MS
    NARAGHI, FF
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (02) : 152 - 157