Biomechanical comparison of intramedullary nail and blade plate fixation for tibiotalocalcaneal arthrodesis

被引:66
|
作者
Alfahd, UA [1 ]
Roth, SE [1 ]
Stephen, D [1 ]
Whyne, CM [1 ]
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Orthopaed Biomech Lab, Toronto, ON M4N 3M5, Canada
关键词
tibiotalocalcaneal arthrodesis; biomechanics; retrograde nail; blade plate;
D O I
10.1097/01.bot.0000184142.90448.e3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Tibiotalocalcaneal arthrodesis is used to manage severe bone loss, arthritis, and/or instability. The goal is to relieve pain through a stable, well-aligned hindfoot and ankle. The purpose of this study was 2-fold: to biomechanically compare 1) initial stability and 2) the effect of bone density on the stability of intramedullary nail and blade plate fixation in tibiotalocalcaneal arthrodesis. Design: Biomechanical study using anatomic specimens. Methods: Ankle and subtalar joint capsules were exposed for 7 pairs of fresh-frozen anatomic specimens. One ankle from each pair was instrumented with an interlocked intramedullary nail inserted retrograde across the subtalar and ankle joint while the contralateral hind foot was stabilized with a lateral cannulated blade plate. Specimen stability was tested in plantar/dorsiflexion and inversion/eversion to a maximum bending moment of 12 Nm and in internal/extemal rotation to a maximum torque of 7 Nm. Physical measurements of bone density were made to determine its effect on stability. Main Outcome Measures: Maximum angular displacement of the constructs in plantarflexion, dorsiflexion, inversion, eversion, internal rotation, and external rotation. Results: No significant differences were observed between the plated and nailed constructs in the 3 loading configurations (Power = 0.77). Only 6 pairs were included in the results because of fixation failures. A small but significant reduction in internal rotation alone of 1.8 degrees was found with the plated compared with the nailed construct (P = 0.045). Reduced stability was associated with lower bone density in torsion and inversion/eversion in the plated constructs (r(2) = 0.67- 0.87) with a similar trend seen in torsion in the nailed constructs (r(2) = 0.5). Conclusion: Initial construct stabilities and the effect of reduced bone density were found to be similar between the blade plate and the intramedullary nail in tibiotalocalcaneal arthrodesis, thus implant choice may be based on other clinical factors, such as surgeon preference or soft-tissue status.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [1] Biomechanical Comparison of Blade Plate and Intramedullary Nail Fixation for Tibiocalcaneal Arthrodesis
    Lee, Arthur T.
    Sundberg, Eric B.
    Lindsey, Derek P.
    Harris, Alex H. S.
    Chou, Loretta B.
    [J]. FOOT & ANKLE INTERNATIONAL, 2010, 31 (02) : 164 - 171
  • [2] A biomechanical comparison of intramedullary nail and crossed lag screw fixation for tibiotalocalcaneal arthrodesis
    Berend, ME
    Glisson, RR
    Nunley, JA
    [J]. FOOT & ANKLE INTERNATIONAL, 1997, 18 (10) : 639 - 643
  • [3] Intramedullary rod fixation compared with blade-plate-and-screw fixation for tibiotalocalcaneal arthrodesis: A biomechanical investigation
    Chiodo, CP
    Acevedo, JI
    Sammarco, VJ
    Parks, BG
    Boucher, HR
    Myerson, MS
    Schon, LC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2425 - 2428
  • [4] Rigidity comparison of locking plate and intramedullary fixation for tibiotalocalcaneal arthrodesis
    O'Neill, Patrick J.
    Logel, Kevin J.
    Parks, Brent G.
    Schon, Lew C.
    [J]. FOOT & ANKLE INTERNATIONAL, 2008, 29 (06) : 581 - 586
  • [5] Locking plate versus retrograde intramedullary nail fixation for tibiotalocalcaneal arthrodesis A retrospective analysis
    Zhang, Chi
    Shi, Zhongmin
    Mei, Guohua
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 227 - 232
  • [6] Tibiotalocalcaneal arthrodesis with a retrograde intramedullary nail: A biomechanical analysis of the effect of nail length
    Noonan, T
    Pinzur, M
    Paxinos, O
    Havey, R
    Patwardhin, A
    [J]. FOOT & ANKLE INTERNATIONAL, 2005, 26 (04) : 304 - 308
  • [7] Tibiotalocalcaneal arthrodesis: A biomechanical comparision of multiplanar external fixation with intramedullary fixation
    Santangelo, James R.
    Glisson, Richard R.
    Garras, David N.
    Easley, Mark E.
    [J]. FOOT & ANKLE INTERNATIONAL, 2008, 29 (09) : 936 - 941
  • [8] Tibiotalocalcaneal Arthrodesis Using Retrograde Intramedullary Nail Fixation: Comparison of Patients With and Without Diabetes Mellitus
    Wukich, Dane K.
    Mallory, Brady R.
    Suder, Natalie C.
    Rosario, Bedda L.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (05): : 876 - 882
  • [9] Posterolateral plate fixation with Pantalarlock® is more stable than nail fixation in tibiotalocalcaneal arthrodesis in a biomechanical cadaver study
    Gutteck, N.
    Schilde, S.
    Reichel, M.
    Holtz, A.
    Sahmel, O.
    Hinz, P.
    Kielstein, H.
    Lange, J.
    Delank, K. S.
    Martin, H.
    [J]. FOOT AND ANKLE SURGERY, 2020, 26 (04) : 328 - 333
  • [10] Biomechanical analysis of screw-augmented intramedullary fixation for tibiotalocalcaneal arthrodesis
    O'Neill, Patrick J.
    Parks, Brent G.
    Walsh, Russell
    Simmons, Lucia M.
    Schon, Lew C.
    [J]. FOOT & ANKLE INTERNATIONAL, 2007, 28 (07) : 804 - 809