Estimation of absorbed organ doses and effective dose based on body mass index in digital radiography

被引:4
|
作者
Kim, HyunJi [1 ]
Park, MinSeok [1 ,2 ]
Park, SongYi [1 ,3 ]
Jeong, HoiWoun [4 ,5 ]
Kim, Jungmin [1 ]
Kim, Youhyun [1 ]
机构
[1] Korea Univ, Dept Radiol Sci, Coll Hlth Sci, Seoul 136703, South Korea
[2] Korea Inst Radiol & Med Sci, Seoul 139706, South Korea
[3] Asan Med Ctr, Dept Nucl Med, Seoul 138736, South Korea
[4] Baekseok Culture Univ, Dept Radiol Sci, Chungcheongnam Do 303705, South Korea
[5] Inje Univ, Seoul Paik Hosp, Seoul 100766, South Korea
基金
新加坡国家研究基金会;
关键词
RADIATION; OVERWEIGHT; OBESITY;
D O I
10.1093/rpd/ncs089
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the introduction of digital radiography, patients undergoing radiographic procedures are subject to being overexposed to radiation. Therefore, it is necessary to estimate the absorbed organ dose and the effective dose, which are significant for patient health, along with body type. During chest radiographic examinations conducted in 899 patients for screening, the absorbed dose of the 13 major organs, the average whole-body dose, and two effective doses weighted by factors published in ICRP 60 and ICRP 103 were calculated on the basis of patient information such as height, weight and examination condition, including kilovolt potential, focus-skin distance and entrance surface dose (ESD), using a PC-based Monte Carlo program simulation. It was found that dose per unit ESD had a tendency to decrease with body mass index (BMI). In particular, the absorbed dose for most organs was larger at high voltages (140 kVp) than at low voltages (120 kVp, 100 kVp). In addition, the effective dose which was based on ICRP 60 and ICRP 103 also represented the same tendency in respect of BMI and tube voltage.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [41] Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index
    Peters, SE
    Brennan, PC
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (09) : 2381 - 2387
  • [42] Estimation of the Effective Doses for Digital Linear Tomography of the Chest
    Boriskina, A. N.
    Kamyshanskaya, I. G.
    Vodovatov, A. V.
    Cheremisin, V. M.
    [J]. 6TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE, 2020, 2250
  • [43] Study of Effective Atomic Number, Mass Energy Absorption Coefficient and Absorbed Dose Rate in Human Organ and Tissue Substitutes
    Abady, R. S.
    Sharaf, J. M.
    Imran, M. M.
    Saleh, H. H.
    Alkhateeb, S. B.
    [J]. JORDAN JOURNAL OF PHYSICS, 2023, 16 (03): : 271 - 284
  • [44] MEASUREMENT OF ENTRANCE SKIN DOSE AND ESTIMATION OF ORGAN DOSE DURING PEDIATRIC CHEST RADIOGRAPHY
    Kumaresan, M.
    Kumar, Rajesh
    Biju, K.
    Choubey, Ajay
    Kantharia, S.
    [J]. HEALTH PHYSICS, 2011, 100 (06): : 654 - 657
  • [45] Assessment of organ and size-specific effective doses from cone beam CT (CBCT) in image-guided radiotherapy (IGRT) based on body mass index (BMI)
    Abuhaimed, Abdullah
    Martin, Colin J.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [46] ASSESSMENT OF ABSORBED DOSE IN POSTMENOPAUSAL WOMEN, USING DXA, AND ITS RELATIONSHIP WITH HEIGHT, WEIGHT AND BODY MASS INDEX
    Salamat, M. R.
    Tavakkoli, M. B.
    Abedi, I.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2011, 22 : S574 - S575
  • [47] Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study
    Yoon, Yongsu
    Park, Hyemin
    Kim, Jungmin
    Kim, Jungsu
    Roh, Younghoon
    Tanaka, Nobukazu
    Morishita, Junji
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)
  • [48] ASSOCIATION OF BODY MASS INDEX WITH RADIOGRAPHY FEATURES OF KNEE OSTEOARTHRITIS
    Abbasi, Mahnaz
    Sahebari, Maryam
    Nikoiee, Maryam
    Yazdi, Zohreh
    [J]. OSTEOPOROSIS INTERNATIONAL, 2011, 22 : 397 - 398
  • [49] Absorbed dose calculation considering organ mass variation for patients treated with Luthatera
    Ramirez, E. Mora
    Vergara-Gil, A.
    Ocampo-Ramos, J.
    Pouget, J.
    Kotzki, P.
    Santoro, L.
    Deshayes, E.
    Bardies, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S86 - S86
  • [50] Estimation of effective and organ dose from chest CT
    Almaasfeh, Sultan
    Salahudeen, Abdulrahman
    Salih, Mohammed
    Abukonna, Ahmed
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 204