摘要
Entrance skin dose (ESD) was measured to calculate the organ doses from the anteroposterior (AP) and posteroanterior (PA) chest x-ray projections for pediatric patients in an Indian hospital. High sensitivity tissue-equivalent thermoluminescent dosimeters (TLD, LiF: Mg, Cu, P chips) were used for measuring entrance skin dose. The respective organ doses were calculated using the Monte Carlo method (MCNP 3.1) to simulate the examination set-up and a three-dimensional mathematical phantom for representing an average 5-y-old Indian child. Using this method, conversion coefficients were derived for translating the measured ESD to organ doses. The average measured ESDs for the chest AP and PA projections were 0.305 mGy and 0.171 mGy, respectively. The average calculated organ doses in the AP and the PA projections were 0.196 and 0.086 mSv for the thyroid, 0.167 and 0.045 mSv for the trachea, 0.078 and 0.043 mSv for the lungs, 0.110 and 0.013 mSv for the liver, 0.002 and 0.016 mSv for the bone marrow, 0.024 and 0.002 mSv for the kidneys, and 0.109 and 0.023 mSv for the heart, respectively. The ESD and organ doses can be reduced significantly with the proper radiological technique. According to these results, the chest PA projection should be preferred over the AP projection in pediatric patients. The estimated organ doses for the chest AP and PA projections can be used for the estimation of the associated risk. Health Phys. 100(6): 654-657; 2011
引用
收藏
页码:654 / 657
页数:4
相关论文
共 50 条
  • [1] Measurement of skin entrance exposure with a dose-area-product meter at chest radiography
    Parry, CK
    Chu, RYL
    Eaton, BG
    Chen, CY
    [J]. RADIOLOGY, 1996, 201 (02) : 574 - 575
  • [2] Measurement of Entrance Skin Dose in Radiographic Examinations of Pediatric Patients
    Abdallah, Yousif
    [J]. CURRENT MEDICAL IMAGING, 2021, 17 (11) : 1385 - 1389
  • [3] PATIENT DOSE MEASUREMENT AND DOSE REDUCTION IN CHEST RADIOGRAPHY
    Milatovic, Aleksandra A.
    Spasic Jokic, Vesna M.
    Jovanovic, Slobodan I.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 220 - 225
  • [4] Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization
    Sun, Lue
    Mizuno, Yusuke
    Iwamoto, Mari
    Goto, Takahisa
    Koguchi, Yasuhiro
    Miyamoto, Yuka
    Tsuboi, Koji
    Chida, Koichi
    Moritake, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1122 - 1130
  • [5] IMPACT OF TUBE VOLTAGE AND FILTRATION ON PEDIATRIC DOSE DURING CHEST RADIOGRAPHY
    Shatskiy, Ilya
    Vodovatov, Alexander
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 92 - 95
  • [6] Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems
    Sun, Zhonghua
    Lin, Chenghsun
    Tyan, YeuSheng
    Ng, Kwan-Hoong
    [J]. CLINICAL IMAGING, 2012, 36 (04) : 279 - 286
  • [8] Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography
    Karami, Vahid
    Zabihzadeh, Mansour
    Gholami, Mehrdad
    Shams, Nasim
    Nezhad, Zahra Fazeli
    [J]. INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2016, 4 (07): : 2183 - 2191
  • [9] Entrance skin dosimetry and size-specific dose estimate from pediatric chest CTA
    Westra, Sjirk J.
    Li, Xinhua
    Gulati, Kavita
    Singh, Sarabjeet
    Liu, Bob
    Kalra, Mannudeep K.
    Abbara, Suhny
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (02) : 97 - 107
  • [10] Entrance skin dose assessment of selected computed radiography facilities in Ghana
    Gyan, E.
    Inkoom, S.
    Amoako, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 817 - 823