MEASUREMENT OF ENTRANCE SKIN DOSE AND ESTIMATION OF ORGAN DOSE DURING PEDIATRIC CHEST RADIOGRAPHY

被引:4
|
作者
Kumaresan, M. [1 ]
Kumar, Rajesh [2 ]
Biju, K. [2 ]
Choubey, Ajay [1 ]
Kantharia, S. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Med, Dept Radiol, Bombay 400094, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Bombay 40094, Maharashtra, India
来源
HEALTH PHYSICS | 2011年 / 100卷 / 06期
关键词
health effects; medical radiation; radiation risk; x rays;
D O I
10.1097/HP.0b013e3182092963
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Entrance skin dose (ESD) was measured to calculate the organ doses from the anteroposterior (AP) and posteroanterior (PA) chest x-ray projections for pediatric patients in an Indian hospital. High sensitivity tissue-equivalent thermoluminescent dosimeters (TLD, LiF: Mg, Cu, P chips) were used for measuring entrance skin dose. The respective organ doses were calculated using the Monte Carlo method (MCNP 3.1) to simulate the examination set-up and a three-dimensional mathematical phantom for representing an average 5-y-old Indian child. Using this method, conversion coefficients were derived for translating the measured ESD to organ doses. The average measured ESDs for the chest AP and PA projections were 0.305 mGy and 0.171 mGy, respectively. The average calculated organ doses in the AP and the PA projections were 0.196 and 0.086 mSv for the thyroid, 0.167 and 0.045 mSv for the trachea, 0.078 and 0.043 mSv for the lungs, 0.110 and 0.013 mSv for the liver, 0.002 and 0.016 mSv for the bone marrow, 0.024 and 0.002 mSv for the kidneys, and 0.109 and 0.023 mSv for the heart, respectively. The ESD and organ doses can be reduced significantly with the proper radiological technique. According to these results, the chest PA projection should be preferred over the AP projection in pediatric patients. The estimated organ doses for the chest AP and PA projections can be used for the estimation of the associated risk. Health Phys. 100(6): 654-657; 2011
引用
收藏
页码:654 / 657
页数:4
相关论文
共 50 条
  • [41] Comparison of organ dose from chest radiography with varying beam quality and constant exposure index
    Nakanishi, Kohei
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (03) : 1143 - 1151
  • [42] Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    [J]. RADIOLOGY, 2017, 282 (03) : 842 - 849
  • [43] Thermoluminescence measurements of entrance surface skin dose in exams of dog's chest in veterinary radiology
    Veneziani, G. R.
    Matsushima, L. C.
    Fernandez, R. M.
    Rodrigues, L. L.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (3-6) : 733 - 735
  • [44] Comparison of organ dose from chest radiography with varying beam quality and constant exposure index
    Kohei Nakanishi
    [J]. Physical and Engineering Sciences in Medicine, 2023, 46 : 1143 - 1151
  • [45] A DETAILED STUDY OF RADIATION-DOSE AND RADIOGRAPHIC TECHNIQUE DURING CHEST RADIOGRAPHY
    FAULKNER, K
    GORDON, MDH
    MILLER, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (699): : 245 - 249
  • [46] Organ Doses and Effective Doses in Pediatric Radiography: Patient-Dose Survey in Finland
    Kiljunen, T.
    Tietavainen, A.
    Parviainen, T.
    Viitala, A.
    Kortesniemi, M.
    [J]. ACTA RADIOLOGICA, 2009, 50 (01) : 114 - U16
  • [47] Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions
    Ralf Kurt Willy Schulze
    Catrin Cremers
    Heiko Karle
    Hugo de las Heras Gala
    [J]. Clinical Oral Investigations, 2017, 21 : 1327 - 1333
  • [48] ENTRANCE DOSE MEASUREMENTS ON PATIENTS AND THEIR RELATION TO ORGAN DOSES
    STIEVE, FE
    ZANKL, M
    NAHRSTEDT, U
    KUHNEL, A
    SCHULT, S
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 161 - 163
  • [49] Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions
    Schulze, Ralf Kurt Willy
    Cremers, Catrin
    Karle, Heiko
    Gala, Hugo de las Heras
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1327 - 1333
  • [50] INFORMATION ENHANCEMENT AND DOSE REDUCTION IN CHEST RADIOGRAPHY - INTERGATED RADIOGRAPHY SYSTEM
    DINSMORE, RE
    WERNIKOFF, RE
    MILLER, SW
    POTSAID, MS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) : 205 - 205