Friction Measurement in the Biaxial Rocking Motion Hip Joint Simulator

被引:13
|
作者
Saikko, Vesa [1 ]
机构
[1] Aalto Univ, Dept Engn Design & Prod, FIN-02015 Helsinki, Finland
来源
基金
芬兰科学院;
关键词
biomechanics; bone; friction; prosthetics; wear; SLIDE TRACK ANALYSIS; WEAR; POLYETHYLENE; CUPS; COCR;
D O I
10.1115/1.2991121
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The established biaxial rocking motion (BRM) hip joint simulator was complemented by a novel friction measurement accessory. This simple and practical system, which was easily added to an existing BRM design, is described in detail and shown to perform well in long-term wear tests and in comparative tests of 24 h duration involving several different bearing couples. The system was based on the measurement of frictional torque about the leaning axis of the lower component, the femoral head. In the 28 mm CoCr-on-ultrahigh molecular weight polyethylene articulation with diluted calf serum lubricant at body temperature and 1 kN static load, the maximum value of frictional torque during a cycle was 1.2 N m on the average. The alternative system based on the measurement of torque about the vertical loading axis was shown to be less sensitive and highly insensitive when contact area was small, as was the case with alumina-on-alumina.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] Control system for an elbow joint motion simulator
    Schimoler, Patrick J.
    Vipperman, Jeffrey S.
    Kuxhaus, Laurel
    Flamm, Angela M.
    Budny, Daniel D.
    Baratz, Mark E.
    Miller, Mark Carl
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINERING CONGRESS AND EXPOSITION 2007, VOL 9, PTS A-C: MECHANICAL SYSTEMS AND CONTROL, 2008, : 215 - 221
  • [22] Design of a Hip Joint Simulator According to the ISO 14242
    Galanis, Nikolaos I.
    Manolakos, Dimitrios E.
    WORLD CONGRESS ON ENGINEERING, WCE 2011, VOL III, 2011, : 2088 - 2093
  • [23] CHOICE OF A RATIONAL HIP JOINT WEAR SIMULATOR DESIGN
    Pakhaliuk, Volodymyr
    Pashkov, Yevgen
    Desyatov, Ivan
    Manchuk, Vitaly
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1559 - 1560
  • [24] Computational hip joint simulator for wear and heat generation
    Fialho, Jorge C.
    Fernandes, Paulo R.
    Eca, Luis
    Folgado, Joao
    JOURNAL OF BIOMECHANICS, 2007, 40 (11) : 2358 - 2366
  • [25] A 12-station anatomic hip joint simulator
    Saikko, V
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H6) : 437 - 448
  • [26] Functional range of motion of the hip joint
    Adam, P.
    Beguin, L.
    Grosclaude, S.
    Jobard, B.
    Fessy, M. -H.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (04): : 382 - 391
  • [27] Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint
    Stolowski, Lukasz
    Niedziela, Maciej
    Lubiatowski, Bartlomiej
    Lubiatowski, Przemyslaw
    Piontek, Tomasz
    SENSORS, 2023, 23 (21)
  • [28] A triaxial physiological hip joint simulator for the wear testing of hip joint prostheses - Drive and control principles
    Springstein, D
    Wendt, Z
    Boenick, U
    BIOMEDIZINISCHE TECHNIK, 2003, 48 (04): : 106 - 109
  • [29] Low wear and friction in alumina/alumina total hip joints - A hip simulator study
    Saikko, V
    Pfaff, HG
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 443 - 448
  • [30] A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    Barbour, PSM
    Stone, MH
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 455 - 467