Friction Measurement in the Biaxial Rocking Motion Hip Joint Simulator

被引:13
|
作者
Saikko, Vesa [1 ]
机构
[1] Aalto Univ, Dept Engn Design & Prod, FIN-02015 Helsinki, Finland
来源
基金
芬兰科学院;
关键词
biomechanics; bone; friction; prosthetics; wear; SLIDE TRACK ANALYSIS; WEAR; POLYETHYLENE; CUPS; COCR;
D O I
10.1115/1.2991121
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The established biaxial rocking motion (BRM) hip joint simulator was complemented by a novel friction measurement accessory. This simple and practical system, which was easily added to an existing BRM design, is described in detail and shown to perform well in long-term wear tests and in comparative tests of 24 h duration involving several different bearing couples. The system was based on the measurement of frictional torque about the leaning axis of the lower component, the femoral head. In the 28 mm CoCr-on-ultrahigh molecular weight polyethylene articulation with diluted calf serum lubricant at body temperature and 1 kN static load, the maximum value of frictional torque during a cycle was 1.2 N m on the average. The alternative system based on the measurement of torque about the vertical loading axis was shown to be less sensitive and highly insensitive when contact area was small, as was the case with alumina-on-alumina.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion
    Charlton, Paula C.
    Mentiplay, Benjamin F.
    Pua, Yong-Hao
    Clark, Ross A.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (03) : 262 - 267
  • [32] Comparison of Motion Disturbance Characteristics between Traditional Load Simulator and Friction Load Simulator
    Jing Chenghu
    Xu Hongguang
    2016 3RD INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE), 2016, : 889 - 893
  • [33] PRACTICABLE MEASUREMENT OF JOINT MOTION
    BAUER, R
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1982, 132 (23-2) : 570 - 574
  • [34] Development of a Mandibular Motion Simulator for Total Joint Replacement
    Celebi, Nukhet
    Rohner, E. Carlos
    Gateno, Jaime
    Noble, Philip C.
    Ismaily, Sabir K.
    Teichgraeber, John F.
    Xia, James J.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (01) : 66 - 79
  • [35] Control of a wrist joint motion simulator: A phantom study
    Shah, Darshan S.
    Kedgley, Angela E.
    JOURNAL OF BIOMECHANICS, 2016, 49 (13) : 3061 - 3068
  • [36] FRICTION TORQUE STUDIES OF TOTAL JOINT REPLACEMENTS USE OF A SIMULATOR
    SCALES, JT
    KELLY, P
    GODDARD, D
    ANNALS OF THE RHEUMATIC DISEASES, 1969, 28 (5S) : 30 - &
  • [37] OBJECTIVE CRITERIA FOR THE MEASUREMENT OF MOTION AT THE HIP
    MILCH, H
    ANATOMICAL RECORD, 1960, 136 (02): : 242 - 243
  • [38] Simultaneous measurement of friction and wear in hip simulators
    Haider, Hani
    Weisenburger, Joel N.
    Garvin, Kevin L.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (05) : 373 - 388
  • [39] Control of an Artificial-Hip-Joint Simulator to Evaluate Dislocation
    Kiguchi, Kazuo
    Yamashita, Akira
    Sasaki, Makoto
    Ueno, Masaru
    Kobayashi, Tsuneyuki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 1647 - +
  • [40] Fatigue Life and Reliability Analysis of a Parallel Hip Joint Simulator
    Guo, Feng
    Cheng, Gang
    Yuan, Xin
    ROBOTICA, 2021, 39 (11) : 2079 - 2093