Friction Measurement in the Biaxial Rocking Motion Hip Joint Simulator

被引:13
|
作者
Saikko, Vesa [1 ]
机构
[1] Aalto Univ, Dept Engn Design & Prod, FIN-02015 Helsinki, Finland
来源
基金
芬兰科学院;
关键词
biomechanics; bone; friction; prosthetics; wear; SLIDE TRACK ANALYSIS; WEAR; POLYETHYLENE; CUPS; COCR;
D O I
10.1115/1.2991121
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The established biaxial rocking motion (BRM) hip joint simulator was complemented by a novel friction measurement accessory. This simple and practical system, which was easily added to an existing BRM design, is described in detail and shown to perform well in long-term wear tests and in comparative tests of 24 h duration involving several different bearing couples. The system was based on the measurement of frictional torque about the leaning axis of the lower component, the femoral head. In the 28 mm CoCr-on-ultrahigh molecular weight polyethylene articulation with diluted calf serum lubricant at body temperature and 1 kN static load, the maximum value of frictional torque during a cycle was 1.2 N m on the average. The alternative system based on the measurement of torque about the vertical loading axis was shown to be less sensitive and highly insensitive when contact area was small, as was the case with alumina-on-alumina.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Friction measurement in a hip wear simulator
    Saikko, Vesa
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (05) : 366 - 372
  • [2] Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator
    Saikko, V
    Calonius, O
    Keränen, J
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 65B (01): : 186 - 192
  • [3] Simplified motion and loading compared to physiological motion and loading in a hip joint simulator
    Smith, SL
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H3) : 233 - 238
  • [4] Friction Compensation in Trajectory Tracking Control for a Parallel Hip Joint Simulator
    Shan, Xianlei
    Cheng, Gang
    Chen, Xihui
    MECHANISM AND MACHINE SCIENCE, 2017, 408 : 143 - 153
  • [5] Three-axis hip joint simulator for wear and friction studies on total hip prostheses
    Saikko, Vesa O.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996, 210 (03) : 175 - 185
  • [6] A Study of the Effect of the Femoral Head Diameter on Prosthetic Hip Joint Dislocation Using a Hip-Joint Motion Simulator
    Kiguchi, Kazuo
    Horie, Toru
    Yamashita, Akira
    Ueno, Masaru
    Kobayashi, Tsuneyuki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6058 - +
  • [7] Evaluation of a hip joint simulator
    Smith, SL
    Burgess, IC
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 469 - 473
  • [8] Design and manufacturing of a hip joint motion simulator with a novel modular design approach
    Shams Torabnia
    Senay Mihcin
    Ismail Lazoglu
    International Journal on Interactive Design and Manufacturing (IJIDeM), 2024, 18 : 401 - 417
  • [9] Design and manufacturing of a hip joint motion simulator with a novel modular design approach
    Torabnia, Shams
    Mihcin, Senay
    Lazoglu, Ismail
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2024, 18 (01): : 401 - 417
  • [10] VEXLPE friction studied with a multidirectional hip joint simulator using contact temperature control
    Saikko, Vesa
    TRIBOLOGY INTERNATIONAL, 2023, 187