Label free polyaniline based impedimetric biosensor for detection of E. coli O157:H7 Bacteria

被引:98
|
作者
Chowdhury, Ankan Dutta [1 ]
De, Amitabha [1 ]
Chaudhuri, Chirosree Roy [2 ]
Bandyopadhyay, Krishnan [3 ]
Sen, Pintu [4 ]
机构
[1] Saha Inst Nucl Phys, Div Chem Sci, Kolkata 700064, W Bengal, India
[2] Bengal Engn & Sci Univ Shibpur, Dept Elect & Telecommun Engn, Sibpur, W Bengal, India
[3] Bengal Engn & Sci Univ Shibpur, Sch Mat Sci & Engn, Sibpur, W Bengal, India
[4] Ctr Variable Energy Cyclotron, Dept Phys, Kolkata 700064, W Bengal, India
来源
关键词
Antibody-antigen binding; Biosensor; Impedimetric sensor; Polyaniline; Bacteria detection; ESCHERICHIA-COLI; ELECTROCHEMICAL DETECTION; NANOPARTICLE; O157-H7; IMMUNOSENSOR; CELLS;
D O I
10.1016/j.snb.2012.06.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and simple method for label free, rapid and inexpensive impedimetric sensing of Escherichia coli O157:H7 (a highly infectious and potentially fatal food and water borne pathogen) using antibody-antigen binding method based on covalently linked antibody on a conducting Polyaniline (PANI) film surface is reported. Electrochemical impedance spectroscopy (EIS) was used to test the sensitivity and effectiveness of the sensor electrode by measuring the change in impedance values of electrodes before and after incubation with different concentrations of bacteria. An equivalent electrical circuit model has also been proposed to explain the sensing mechanism. As small concentration as 10(2) CFU mL(-1) of E. coli O157:H7 were successfully detected on the Au/PANI/Glu/antibody sensor with the upper detection limit of 10(7) CFU mL(-1). The specificity of the sensor has been tested by comparing with two other strains of similar bacteria and found to be satisfactory. The mechanism of the detection is very simple and rapid, giving it a major advantage over DNA based techniques and other secondary antibody based labeled methods. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:916 / 923
页数:8
相关论文
共 50 条
  • [21] Confirmation of viable E. coli O157:H7 by enrichment and PCR after rapid biosensor detection
    Tims, TB
    Lim, DV
    JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 55 (01) : 141 - 147
  • [22] Novel impedimetric aptasensor for label-free detection of Escherichia coil O157:H7
    Brosel-Oliu, Sergi
    Ferreira, Ruben
    Uria, Naroa
    Abramova, Natalia
    Gargallo, Raimundo
    Munoz-Pascual, Francesc-Xavier
    Bratov, Andrey
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2988 - 2995
  • [23] A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection
    Abu Bakar, M. H.
    Ibrahim, M. H.
    Kassim, N. M.
    Mohammad, A. B.
    2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 51 - 54
  • [24] Electrical DNA Biosensor using Aluminium Interdigitated Electrode for E. Coli O157:H7 detection
    Natasha, N. Z.
    Rajapaksha, R. D. A. A.
    Uda, M. N. A.
    Hashim, U.
    3RD ELECTRONIC AND GREEN MATERIALS INTERNATIONAL CONFERENCE 2017 (EGM 2017), 2017, 1885
  • [25] Evaluation of the GENE-UP ® E. coli O157:H7 Method for the Detection of E. coli O157:H7 in Select Foods: Collaborative Study, 2019.03
    Johnson, Ronald
    Mills, John
    Pittet, Jean-Louis
    Rannou, Maryse
    Bird, Patrick
    Nelson, Maria
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (05) : 1338 - 1347
  • [26] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [27] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [28] NaBiF4 upconversion nanoparticle-based electrochemiluminescent biosensor for E. coli O157: H7 detection
    Liu, Danqing
    Lv, Xingxing
    Zhao, Chaoyue
    Li, Jiayue
    Huang, Jinmei
    Weng, Ling
    He, Liangcan
    Liu, Shaoqin
    RSC ADVANCES, 2022, 12 (46) : 30174 - 30180
  • [29] A colorimetric biosensor with infrared sterilization based on CuSe nanoparticles for the detection of E. coli O157:H7 in food samples
    Guo, Yulan
    Zhao, Jinbin
    Ma, Xueer
    Cai, Ming
    Liu, Shitong
    Sun, Chunmeng
    Chi, Yuyang
    Xu, Kun
    MICROBIOLOGY SPECTRUM, 2024, 12 (08):
  • [30] Evaluation of the GENE-UP VR E. Coli O157:H7 method for the detection of E. coli O157:H7 in select foods: Collaborative study, 2019.03
    Johnson R.
    Mills J.
    Pittet J.-L.
    Rannou M.
    Bird P.
    Nelson M.
    Journal of AOAC International, 2021, 103 (05) : 1338 - 1347