A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection

被引:0
|
作者
Abu Bakar, M. H. [1 ]
Ibrahim, M. H. [1 ]
Kassim, N. M. [1 ]
Mohammad, A. B. [1 ]
机构
[1] Univ Teknol Malaysia, Ctr Photon Technol, Fac Elect Engn, Skudai 81310, Johor, Malaysia
关键词
MEMS; Microcantilever; Piezoresistive; Immunosensor; Escherichia coli; O157:H7; Surface stress; Biosensor; antibodies; bacteria; detection; PLASMON RESONANCE BIOSENSOR; MICROCANTILEVER; CANTILEVERS; OUTBREAK; SENSORS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Bio-recognition layers on sensors can be designed in various ways; however the most popular approach is to immobilise antibodies for specific capture of analytes also known as immunosensor. This paper presents a preliminary study on MEMS based immunosensor for detecting Escherichia coli O157:H7. In this paper, the recent progress within biosensors for E. coli O157:H7 detection will be reviewed. We will discuss the strengths and limitations of current sensor technologies for the detection of E. coli O157:H7. This paper explores the previous methods that have been employed to detect E. coli O157:H7 based on their detection scheme, detection limit, and response time. The reasons focusing on sensor utilizing specifically defined microcantilever using piezoresistive detection scheme is also discussed. We will also explain briefly on the theoretical aspects governing the relation between surface stress and the bending of the microcantilever.
引用
收藏
页码:51 / 54
页数:4
相关论文
共 50 条
  • [1] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [2] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [3] A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7
    Sobhan, Abdus
    Jia, Fei
    Kelso, Lisa Cooney
    Biswas, Sonatan Kumar
    Muthukumarappan, Kasiviswanathan
    Cao, Changyong
    Wei, Lin
    Li, Yanbin
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [4] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Sara Asgari
    Rajiv Dhital
    S. Ali Aghvami
    Azlin Mustapha
    Yi Zhang
    Mengshi Lin
    Microchimica Acta, 2022, 189
  • [5] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Asgari, Sara
    Dhital, Rajiv
    Aghvami, S. Ali
    Mustapha, Azlin
    Zhang, Yi
    Lin, Mengshi
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [6] Outbreak:: E. coli O157:H7
    Todd, Betsy
    AMERICAN JOURNAL OF NURSING, 2007, 107 (02) : 29 - 30
  • [7] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868
  • [8] E. coli O157:H7 Shedding in Beef Calves Vaccinated with E. coli O157:H7 SRP ® Vaccine Born to Cows Vaccinated Prepartum with E. coli O157:H7 SRP® Vaccine
    Wileman, B. W.
    Thomson, D. U.
    Olson, K. C.
    Pacheco, L. A.
    Jaeger, J. R.
    Bolte, J.
    Proceedings of the Forty-Third Annual Conference of the American Association of Bovine Practitioners, 2010, 2010, : 200 - 200
  • [9] Dendrimeric biosensor for detection of E. coli O157:H7 in diet
    Shende, Pravin
    Kasture, Pooja
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (02): : 5128 - 5131
  • [10] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618