A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection

被引:0
|
作者
Abu Bakar, M. H. [1 ]
Ibrahim, M. H. [1 ]
Kassim, N. M. [1 ]
Mohammad, A. B. [1 ]
机构
[1] Univ Teknol Malaysia, Ctr Photon Technol, Fac Elect Engn, Skudai 81310, Johor, Malaysia
关键词
MEMS; Microcantilever; Piezoresistive; Immunosensor; Escherichia coli; O157:H7; Surface stress; Biosensor; antibodies; bacteria; detection; PLASMON RESONANCE BIOSENSOR; MICROCANTILEVER; CANTILEVERS; OUTBREAK; SENSORS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Bio-recognition layers on sensors can be designed in various ways; however the most popular approach is to immobilise antibodies for specific capture of analytes also known as immunosensor. This paper presents a preliminary study on MEMS based immunosensor for detecting Escherichia coli O157:H7. In this paper, the recent progress within biosensors for E. coli O157:H7 detection will be reviewed. We will discuss the strengths and limitations of current sensor technologies for the detection of E. coli O157:H7. This paper explores the previous methods that have been employed to detect E. coli O157:H7 based on their detection scheme, detection limit, and response time. The reasons focusing on sensor utilizing specifically defined microcantilever using piezoresistive detection scheme is also discussed. We will also explain briefly on the theoretical aspects governing the relation between surface stress and the bending of the microcantilever.
引用
收藏
页码:51 / 54
页数:4
相关论文
共 50 条
  • [41] Signal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
    Jingzhuan Wan
    Junjie Ai
    Yonghua Zhang
    Xiaohui Geng
    Qiang Gao
    Zhiliang Cheng
    Scientific Reports, 6
  • [42] Signal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
    Wan, Jingzhuan
    Ai, Junjie
    Zhang, Yonghua
    Geng, Xiaohui
    Gao, Qiang
    Cheng, Zhiliang
    SCIENTIFIC REPORTS, 2016, 6
  • [43] Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic network
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1253 - 1258
  • [44] Detection and enumeration of E. coli O157:H7 in water samples by culture and molecular methods
    Ngwa, G. A.
    Schop, R.
    Weir, S.
    Leon-Velarde, C. G.
    Odumeru, J. A.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 92 (02) : 164 - 172
  • [45] Detection of E. coli O157 : H7 from the sheep and goats raw milk in Turkey
    Ulukanli, Zeynep
    Genctav, Kenan
    Tuzcu, Mehmet
    Elmali, Mehmet
    Yaman, Hilmi
    INDIAN VETERINARY JOURNAL, 2006, 83 (09): : 1009 - 1010
  • [46] Detection of E. coli O157:H7 using its endogenous active membrane peroxidase
    Shim K.H.
    Kang M.
    Kim M.G.
    Chung B.H.
    An S.S.A.
    Toxicology and Environmental Health Sciences, 2011, 3 (2) : 80 - 85
  • [47] Detection of escherichia coli O157:H7 using interdigitated array microelectrode-based immunosensor
    Wang Y.
    Wang R.
    Li Y.
    Srinivasan B.
    Tung S.
    Wang H.
    Slavik M.F.
    Griffis C.L.
    Biological Engineering, 2010, 2 (02): : 49 - 62
  • [48] Evaluation of hha and hha sepB mutant strains of Escherichia coli O157:H7 as bacterins for reducing E. coli O157:H7 shedding in cattle
    Sharma, Vijay K.
    Dean-Nystrom, Evelyn A.
    Casey, Thomas A.
    VACCINE, 2011, 29 (31) : 5078 - 5086
  • [49] On the trial of E-coli O157:H7
    Lewis, R
    SCIENTIST, 1999, 13 (21): : 10 - 10
  • [50] Identification of LexA dependent promoters in E. coli O157:H7 genome
    Yaguchi, Kazuya
    Mikami, Takashi
    Igari, Kazuki
    Yoshida, Yuusuke
    Yokoyama, Katsushi
    Makino, Kouzou
    GENES & GENETIC SYSTEMS, 2010, 85 (06) : 422 - 422