A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7

被引:14
|
作者
Sobhan, Abdus [1 ,2 ]
Jia, Fei [1 ]
Kelso, Lisa Cooney [1 ]
Biswas, Sonatan Kumar [1 ]
Muthukumarappan, Kasiviswanathan [2 ]
Cao, Changyong [3 ,4 ]
Wei, Lin [2 ]
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[2] South Dakota State Univ, Dept Agr & Biosyst Engn, Brookings, SD 57007 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Louis Stokes Cleveland VA Med Ctr, Adv Platform Technol APT, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
electrochemical immunosensor; rapid detection; activated biochar; biosensor; Escherichia coli O157:H7; ELECTROCHEMICAL BIOSENSOR; YERSINIA-ENTEROCOLITICA; NANOPARTICLES; ELECTRODE;
D O I
10.3390/bios12100908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E. coli O157:H7, one of the major foodborne pathogens, can cause a significant threat to the safety of foods. The aim of this research is to develop an activated biochar-based immunosensor that can rapidly detect E. coli O157:H7 cells without incubation in pure culture. Biochar was developed from corn stalks using proprietary reactors and then activated using steam-activation treatment. The developed activated biochar presented an enhanced surface area of 830.78 m(2)/g. To develop the biosensor, the gold electrode of the sensor was first coated with activated biochar and then functionalized with streptavidin as a linker and further immobilized with biotin-labeled anti-E. coli polyclonal antibodies (pAbs). The optimum concentration of activated biochar for sensor development was determined to be 20 mg/mL. Binding of anti-E. coli pAbs with E. coli O157:H7 resulted in a significant increase in impedance amplitude from 3.5 to 8.5 k omega when compared to an only activated biochar-coated electrode. The developed immunosensor was able to detect E. coli O157:H7 cells with a limit of detection of 4 log CFU/mL without incubation. Successful binding of E. coli O157:H7 onto an activated biochar-based immunosensor was observed on the microelectrode surface in scanning electron microscopy (SEM) images.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [2] A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection
    Abu Bakar, M. H.
    Ibrahim, M. H.
    Kassim, N. M.
    Mohammad, A. B.
    2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 51 - 54
  • [3] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [4] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Sara Asgari
    Rajiv Dhital
    S. Ali Aghvami
    Azlin Mustapha
    Yi Zhang
    Mengshi Lin
    Microchimica Acta, 2022, 189
  • [5] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Asgari, Sara
    Dhital, Rajiv
    Aghvami, S. Ali
    Mustapha, Azlin
    Zhang, Yi
    Lin, Mengshi
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [6] Outbreak:: E. coli O157:H7
    Todd, Betsy
    AMERICAN JOURNAL OF NURSING, 2007, 107 (02) : 29 - 30
  • [7] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868
  • [8] Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Jophy, Chesna
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [9] A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    Dastider, Shibajyoti Ghosh
    Barizuddin, Syed
    Dweik, Majed
    Almasri, Mahmoud
    RSC ADVANCES, 2013, 3 (48): : 26297 - 26306
  • [10] E. coli O157:H7 Shedding in Beef Calves Vaccinated with E. coli O157:H7 SRP ® Vaccine Born to Cows Vaccinated Prepartum with E. coli O157:H7 SRP® Vaccine
    Wileman, B. W.
    Thomson, D. U.
    Olson, K. C.
    Pacheco, L. A.
    Jaeger, J. R.
    Bolte, J.
    Proceedings of the Forty-Third Annual Conference of the American Association of Bovine Practitioners, 2010, 2010, : 200 - 200