A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7

被引:14
|
作者
Sobhan, Abdus [1 ,2 ]
Jia, Fei [1 ]
Kelso, Lisa Cooney [1 ]
Biswas, Sonatan Kumar [1 ]
Muthukumarappan, Kasiviswanathan [2 ]
Cao, Changyong [3 ,4 ]
Wei, Lin [2 ]
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[2] South Dakota State Univ, Dept Agr & Biosyst Engn, Brookings, SD 57007 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Louis Stokes Cleveland VA Med Ctr, Adv Platform Technol APT, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
electrochemical immunosensor; rapid detection; activated biochar; biosensor; Escherichia coli O157:H7; ELECTROCHEMICAL BIOSENSOR; YERSINIA-ENTEROCOLITICA; NANOPARTICLES; ELECTRODE;
D O I
10.3390/bios12100908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E. coli O157:H7, one of the major foodborne pathogens, can cause a significant threat to the safety of foods. The aim of this research is to develop an activated biochar-based immunosensor that can rapidly detect E. coli O157:H7 cells without incubation in pure culture. Biochar was developed from corn stalks using proprietary reactors and then activated using steam-activation treatment. The developed activated biochar presented an enhanced surface area of 830.78 m(2)/g. To develop the biosensor, the gold electrode of the sensor was first coated with activated biochar and then functionalized with streptavidin as a linker and further immobilized with biotin-labeled anti-E. coli polyclonal antibodies (pAbs). The optimum concentration of activated biochar for sensor development was determined to be 20 mg/mL. Binding of anti-E. coli pAbs with E. coli O157:H7 resulted in a significant increase in impedance amplitude from 3.5 to 8.5 k omega when compared to an only activated biochar-coated electrode. The developed immunosensor was able to detect E. coli O157:H7 cells with a limit of detection of 4 log CFU/mL without incubation. Successful binding of E. coli O157:H7 onto an activated biochar-based immunosensor was observed on the microelectrode surface in scanning electron microscopy (SEM) images.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Confirmation of viable E. coli O157:H7 by enrichment and PCR after rapid biosensor detection
    Tims, TB
    Lim, DV
    JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 55 (01) : 141 - 147
  • [22] Rapid and sensitive detection of E. coli O157:H7 by lateral flow immunoassay and silver enhancement
    Shayesteh Bazsefidpar
    Esther Serrano-Pertierra
    Gemma Gutiérrez
    Alberto Sánchez Calvo
    María Matos
    María Carmen Blanco-López
    Microchimica Acta, 2023, 190
  • [23] Rapid and selective detection of E. coli O157:H7 combining phagomagnetic separation with enzymatic colorimetry
    Zhang, Yun
    Yan, Chenghui
    Yang, Hang
    Yu, Junping
    Wei, Hongping
    FOOD CHEMISTRY, 2017, 234 : 332 - 338
  • [24] A systemic vaccine based on Escherichia coli O157:H7 bacterial ghosts (BGs) reduces the excretion of E. coli O157:H7 in calves
    Vilte, D. A.
    Larzabal, M.
    Mayr, U. B.
    Garbaccio, S.
    Gammella, M.
    Rabinovitz, B. C.
    Delgado, F.
    Meikle, V.
    Cantet, R. J. C.
    Lubitz, P.
    Lubitz, W.
    Cataldi, A.
    Mercado, E. C.
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2012, 146 (02) : 169 - 176
  • [25] Amperometric immunosensor for the detection of Escherichia coli O157:H7 in food specimens
    Li, Yan
    Cheng, Ping
    Gong, Junhua
    Fang, Lichao
    Deng, Jun
    Liang, Wenbin
    Zheng, Junsong
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (01) : 227 - 233
  • [26] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [27] QCM immunosensor with nanoparticle amplification for detection of Escherichia coli O157:H7
    Fei Liu
    Yanbin Li
    Xiao-Li Su
    Michael F. Slavik
    Yibin Ying
    Jianping Wang
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (4): : 161 - 168
  • [28] A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7
    Sun, Dongli
    Fan, Tingting
    Liu, Feng
    Wang, Fangxiu
    Gao, Dan
    Lin, Jin-Ming
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [29] An Anti E. Coli O157:H7 Antibody-Immobilized Microcantilever for the Detection of Escherichia Coli (E. coli)
    Jing Zhang
    Hai-Feng Ji
    Analytical Sciences, 2004, 20 : 585 - 587
  • [30] Immunosensor for detection of Escherichia coli O157:H7 using imaging ellipsometry
    Bae, Young Min
    Park, Kwang-Won
    Oh, Byung-Keun
    Choi, Jeong-Woo
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2006, 16 (08) : 1169 - 1173