QCM immunosensor with nanoparticle amplification for detection of Escherichia coli O157:H7

被引:19
|
作者
Fei Liu
Yanbin Li
Xiao-Li Su
Michael F. Slavik
Yibin Ying
Jianping Wang
机构
[1] University of Arkansas,Department of Biological and Agricultural Engineering
[2] BioDetection Instruments LLC,Department of Poultry Science
[3] University of Arkansas,College of Biosystems Engineering and Food Science
[4] Zhejiang University,undefined
关键词
Immunosensor; O157:H7; Quartz crystal microbalance; Nanoparticle; Bacteria detection; Food safety;
D O I
10.1007/s11694-007-9021-1
中图分类号
学科分类号
摘要
A quartz crystal microbalance (QCM) immunosensor was developed and evaluated for detection of Escherichia coli O157:H7. The immunosensor was fabricated by self-assembling of protein A and affinity-purified anti-E. coli O157:H7 antibodies on the gold electrode of an AT-cut piezoelectric quartz crystal. To enhance the sensitivity of the QCM immunosensor, nanoparticle-antibody conjugates, which were prepared using streptavidin-conjugated nanoparticles (145 nm diameter) and biotinylated anti-E. coli antibodies, were used for signal amplification. After the binding of E. coli O157:H7 cells with the antibodies immobilized on the electrode, nanoparticle-antibody conjugates were introduced as mass amplifiers. Compared to the direct detection of E. coli O157:H7, the binding of the nanoparticle conjugates further resulted in a decrease in resonant frequency and an increase in resonant resistance, and the detection sensitivity was improved by five orders of magnitude by lowering the detection limit from 107 to 102 CFU/mL. The sensor specificity and nonspecific adsorption of nanoparticle-antibody conjugates were also investigated.
引用
收藏
页码:161 / 168
页数:7
相关论文
共 50 条
  • [1] Amperometric immunosensor for the detection of Escherichia coli O157:H7 in food specimens
    Li, Yan
    Cheng, Ping
    Gong, Junhua
    Fang, Lichao
    Deng, Jun
    Liang, Wenbin
    Zheng, Junsong
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (01) : 227 - 233
  • [2] Immunosensor for detection of Escherichia coli O157:H7 using imaging ellipsometry
    Bae, Young Min
    Park, Kwang-Won
    Oh, Byung-Keun
    Choi, Jeong-Woo
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2006, 16 (08) : 1169 - 1173
  • [3] Electrochemical Immunosensor Using Nanoparticle-Based Signal Enhancement for Escherichia Coli O157:H7 Detection
    Wang, Yun
    Fewins, Patrick A.
    Alocilja, Evangelyn C.
    IEEE SENSORS JOURNAL, 2015, 15 (08) : 4692 - 4699
  • [4] Signal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
    Jingzhuan Wan
    Junjie Ai
    Yonghua Zhang
    Xiaohui Geng
    Qiang Gao
    Zhiliang Cheng
    Scientific Reports, 6
  • [5] Liposome-based microcapillary immunosensor for detection of Escherichia coli O157:H7
    Ho, JAA
    Hsu, HW
    Huang, MR
    ANALYTICAL BIOCHEMISTRY, 2004, 330 (02) : 342 - 349
  • [6] Signal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
    Wan, Jingzhuan
    Ai, Junjie
    Zhang, Yonghua
    Geng, Xiaohui
    Gao, Qiang
    Cheng, Zhiliang
    SCIENTIFIC REPORTS, 2016, 6
  • [7] Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic network
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1253 - 1258
  • [8] Escherichia coli O157:H7
    Weir, E
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2000, 163 (02) : 205 - 205
  • [9] Escherichia coli O157:H7
    Hartigan, PJ
    IRISH VETERINARY JOURNAL, 1997, 50 (02) : 91 - +
  • [10] Escherichia coli O157:H7
    Riemann, HP
    Cliver, DO
    VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1998, 14 (01) : 41 - +