Evaluation of the GENE-UP VR E. Coli O157:H7 method for the detection of E. coli O157:H7 in select foods: Collaborative study, 2019.03

被引:0
|
作者
Johnson R. [1 ]
Mills J. [1 ]
Pittet J.-L. [2 ]
Rannou M. [3 ]
Bird P. [4 ]
Nelson M. [4 ]
机构
[1] bioMérieux, Inc., 595 Anglum Road, Hazelwood, 63042, MO
[2] bioMérieux, Inc., Chemin de l’Orme, Marcy L’Etoile
[3] ADRIA Developpement Creac’h Gwen, Quimper Cedex
[4] AOAC International, 2275 Research Blvd. #300, Rockville, 20850, MD
关键词
All Open Access; Bronze;
D O I
10.1093/JAOCINT/QSZ016
中图分类号
学科分类号
摘要
Background: The GENE-UPVR E. coli O157:H7 2 (ECO 2) assay (Performance Tested MethodSM 121805) incorporates Fluorescence Resonance Energy Transfer hybridization probes into its proprietary PCR technology for the rapid detection of E. coli O157:H7 in select foods. Objective: The purpose of this validation was to evaluate the method’s interlaboratory performance and submit the result to AOAC INTERNATIONAL for adoption as First Action Official MethodSM for the detection of E. coli O157:H7 in select foods. Method: The GENE-UPVR method was evaluated in a multi-laboratory study as part of the MicroVal validation process using unpaired test portions for one food matrix, raw milk cheese (Comté, 34% fat, 0.8% salt). The candidate method was compared to the ISO 16654:2001 reference method. Fourteen participants from 13 laboratories throughout the European Union participated. Three levels of contamination were evaluated: a non-inoculated control level (0 colony-forming units (CFU)/test portion), a low contamination level (5 CFU/test portion), and a high contamination level (10 CFU/test portion). Data from that study were analyzed according to the Probability of Detection (POD) statistical model as presented in the AOAC validation guidelines. The difference in laboratory POD (dLPODC) values with 95% confidence interval across collaborators was calculated for each level between the candidate and reference method results, and between the candidate presumptive and confirmed results. Results: The dLPODC values with 95% confidence interval were; 0.00 (–0.04, 0.04), 0.27 (0.04, 0.49), and 0.17 (0.01, 0.33) for the non-inoculated, low and high contamination levels respectively. Conclusions: The dLPODC results indicate a significant difference between the candidate method and the reference method for both the low and high contamination levels, with the candidate method producing higher recovery of the target organism at both levels. Highlights: The GENE-UP E. coli O157:H7 assay provides industry with a rapid, accurate detection method for E. coli O157:H7 in a broad range of foods. © AOAC INTERNATIONAL 2020.
引用
收藏
页码:1338 / 1347
页数:9
相关论文
共 50 条
  • [1] Evaluation of the GENE-UP ® E. coli O157:H7 Method for the Detection of E. coli O157:H7 in Select Foods: Collaborative Study, 2019.03
    Johnson, Ronald
    Mills, John
    Pittet, Jean-Louis
    Rannou, Maryse
    Bird, Patrick
    Nelson, Maria
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (05) : 1338 - 1347
  • [2] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [3] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [4] Outbreak:: E. coli O157:H7
    Todd, Betsy
    AMERICAN JOURNAL OF NURSING, 2007, 107 (02) : 29 - 30
  • [5] E. coli O157:H7 Shedding in Beef Calves Vaccinated with E. coli O157:H7 SRP ® Vaccine Born to Cows Vaccinated Prepartum with E. coli O157:H7 SRP® Vaccine
    Wileman, B. W.
    Thomson, D. U.
    Olson, K. C.
    Pacheco, L. A.
    Jaeger, J. R.
    Bolte, J.
    Proceedings of the Forty-Third Annual Conference of the American Association of Bovine Practitioners, 2010, 2010, : 200 - 200
  • [6] Validation of a Modified ANSR® for E-coli O157:H7 Method for Detection of E-coli O157:H7 in Select Foods
    Alles, Susan
    Roman, Brooke
    Quynh-Nhi Le
    Hosking, Edan
    Colangelo, Wesley
    Tovar, Eric
    Biswas, Preetha
    Mozola, Mark
    Donofrio, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (01) : 96 - 107
  • [7] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868
  • [8] E. coli O157:H7 - searching for solutions
    1600, Inst of Food Technologists, Chicago, IL, USA (54):
  • [9] Dendrimeric biosensor for detection of E. coli O157:H7 in diet
    Shende, Pravin
    Kasture, Pooja
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (02): : 5128 - 5131
  • [10] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618