Novel impedimetric aptasensor for label-free detection of Escherichia coil O157:H7

被引:91
|
作者
Brosel-Oliu, Sergi [1 ]
Ferreira, Ruben [1 ]
Uria, Naroa [1 ]
Abramova, Natalia [1 ,2 ]
Gargallo, Raimundo [3 ]
Munoz-Pascual, Francesc-Xavier [1 ]
Bratov, Andrey [1 ]
机构
[1] Esfera UAB CEI, BioMEMS Grp, IMB, CSIC,CNM, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
[3] Univ Barcelona, Dept Chem Engn & Analyt Chem, Barcelona, Spain
基金
欧盟第七框架计划;
关键词
Label-free biosensor; Impedimetric transducer; Aptamer; Three-dimensional interdigitated electrode array; E. coli O157:H7; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; COLI O157H7; PATHOGEN DETECTION; BIOSENSORS; BACTERIA; WATER; PERSPECTIVE; APTAMERS; SENSORS;
D O I
10.1016/j.snb.2017.09.121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microbial safety of drinking water constitutes a major concern in countries at all levels of economic development. Thus, rapid, sensitive and cost effective methods of pathogenic bacteria detection, like common Escherichia coli O157:H7, which can cause important diseases, are highly required. In this work an impedimetric transducer modified with E. coli specific aptamer is studied. To enhance the sensitivity a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer, in which the electrodes are separated by insulating barriers was used. In this sensor chemical reactions at the surface of the barrier provoke electrical charge redistribution which causes changes in the surface conductivity. A DNA aptamer, which recognizes specifically the outer membrane proteins of the E. coli O157:H7, was selected as the biorecognition moiety. Here we report a novel label-free impedimetric aptasensor for detection and quantification of pathogenic E. coli O157:H7 with a low detection limit, good selectivity and short detection time. The developed sensor shows a linear response (R-2 = 0.977), proportional to the logarithm of bacterial concentration present in the sample, with the limit of detection (LOD) of about 10(2) cfu mL(-1). No response of the aptasensor was registered in the presence of other bacterial strains (E. coli k12, Salmonella typhimurium, Staphylococcus aureus), which confirms the selectivity of the suggested detection method. Additionally, the methodology of the aptasensor regeneration was developed, so that the detection may be performed several times with the same sensor. Moreover, suitability of the aptasensor for bacteria detection in real samples was demonstrated with a new approach involving bacteria pre-concentration. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:2988 / 2995
页数:8
相关论文
共 50 条
  • [1] Label-free amperometric biosensor for Escherichia coli O157:H7 detection
    Dhull, Nidhi
    Kaur, Gurpreet
    Jain, Prateek
    Mishra, Priyanka
    Singh, Divya
    Ganju, Lilly
    Gupta, Vinay
    Tomar, Monika
    APPLIED SURFACE SCIENCE, 2019, 495
  • [2] MoS2 nanosheets based label-free colorimetric aptasensor for Escherichia coli O157: H7 detection
    Li, Jiye
    Yun, Wen
    Zhang, Hua
    Chen, Ligang
    Ho, Ho-Pui
    Pu, Xiaoyin
    Huang, Yu
    Shen, Yu
    Cao, Haiyan
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2023, 674
  • [3] Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7
    Wang, Yixian
    Ping, Jianfeng
    Ye, Zunzhong
    Wu, Jian
    Ying, Yibin
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 492 - 498
  • [4] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Huang, Yanyan
    Wu, Zunyi
    Zhao, Guangying
    Dou, Wenchao
    JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (12) : 7960 - 7969
  • [5] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Yanyan Huang
    Zunyi Wu
    Guangying Zhao
    Wenchao Dou
    Journal of Electronic Materials, 2019, 48 : 7960 - 7969
  • [6] Label-free and enzyme-free sensitive fluorescent method for detection of viable Escherichia coli O157:H7
    Chen, Shujuan
    Li, Yongsheng
    Fu, Zhenzhen
    Zeng, Yue
    He, Li
    Zhou, Kang
    Ao, Xiaoling
    Liu, Shuliang
    Zou, Likou
    ANALYTICAL BIOCHEMISTRY, 2018, 556 : 145 - 151
  • [7] Real-time label-free acoustic technology for rapid detection of Escherichia coli O157:H7
    Huang, Ling
    Cooper, Matthew A.
    CLINICAL CHEMISTRY, 2006, 52 (11) : 2148 - 2151
  • [8] Label-free, PCR-free DNA Hybridization Detection of Escherichia coli O157:H7 Based on Electrochemical Nanobiosensor
    Minaei, Mohammad Ebrahim
    Saadati, Mojtaba
    Najafi, Mostafa
    Honari, Hossein
    ELECTROANALYSIS, 2016, 28 (10) : 2582 - 2589
  • [9] Signal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
    Jingzhuan Wan
    Junjie Ai
    Yonghua Zhang
    Xiaohui Geng
    Qiang Gao
    Zhiliang Cheng
    Scientific Reports, 6
  • [10] Sensitive Detection of Escherichia coli O157:H7 in Food Products by Impedimetric Immunosensors
    Malvano, Francesca
    Pilloton, Roberto
    Albanese, Donatella
    SENSORS, 2018, 18 (07)