Depth-profile analysis of thermoelectric layers on Si wafers by pulsed r.f. glow discharge time-of-flight mass spectrometry

被引:14
|
作者
Reinsberg, K. -G. [1 ]
Schumacher, C. [2 ]
Tempez, A. [3 ]
Nielsch, K. [2 ]
Broekaert, J. A. C. [1 ]
机构
[1] Univ Hamburg, Inst Inorgan & Appl Chem, D-20146 Hamburg, Germany
[2] Univ Hamburg, Inst Appl Phys, D-20355 Hamburg, Germany
[3] HORIBA Jobin Yvon, F-91160 Longjumeau, France
关键词
Thermoelectrics; Pulsed r.f. glow discharge; Time-of-flight mass spectrometry; Depthprofiling; BISMUTH TELLURIDE; ELECTRODEPOSITION; OPTIMIZATION; FILMS;
D O I
10.1016/j.sab.2012.06.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work the depth-profile analysis of thermoelectric layers deposited on Au and Cr covered Si wafers with the aid of pulsed radiofrequency glow discharge time-of-flight mass spectrometry (pulsed RF-GD-TOFMS also called plasma profiling TOFMS (PP-TOFMS (TM))) is described. For thermoelectric materials the depth resolutions obtained with both PP-TOFMS and secondary ion mass spectrometry (SIMS) are shown to be well comparable and in the order of the roughness of the corresponding layers (between 20 and 3700 nm). With both methods a direct solid analysis without any preparation steps is possible. In addition, the analysis of the samples with PP-TOFMS proved to be faster by a factor of 26 compared to SIMS, as sputtering rates were found to be 80 nm s(-1) and 3 nm s(-1), respectively. For the analyzed samples the results of PP-TOFMS and SIMS show that a homogeneous deposition was obtained. Quantitative results for all samples could also be obtained directly by PP-TOFMS when the stoichiometry of one sample was determined beforehand for instance by inductively coupled plasma optical emission spectrometry (ICP-OES) and scanning electron microscopy energy dispersive X-ray fluorescence spectrometry (SEM-EDX). For Bi2Te3 the standard deviation for the main component concentrations within one sample then is found to be between 1.1% and 1.9% and it is 3.6% from sample to sample. For Sb2Te3 the values within one sample are from 1.7% to 42% and from sample to sample 5.3%, respectively. (C) 2012 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [31] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    Bouza, Marcos
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (05) : 1108 - 1116
  • [32] Rapid evaluation of different perovskite absorber layers through the application of depth profile analysis using glow discharge - Time of flight mass spectrometry
    Fernandez, Beatriz
    Lobo, Lara
    Tyagi, Priyanka
    Stoichkov, Vasil
    Kettle, Jeff
    Pereiro, Rosario
    TALANTA, 2019, 192 : 317 - 324
  • [33] RF-pulsed glow discharge time-of-flight mass spectrometry for glass analysis: Investigation of the ion source design
    Bouza, Marcos
    Fernandez, Beatriz
    Gonzalez-Gago, Cristina
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2012, 756 : 30 - 36
  • [34] MICROSECOND PULSED GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER
    HANG, W
    YANG, PY
    WANG, XR
    YANG, CL
    SU, YX
    HUANG, BL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) : 590 - 594
  • [35] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, DM
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (12) : 1326 - 1331
  • [36] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, Denise M.
    Hieftje, Gary M.
    Journal of Analytical Atomic Spectrometry, 2005, 20 (12): : 1326 - 1331
  • [37] Direct Quantification of Major and Trace Elements in Geological Samples by Time-of-Flight Mass Spectrometry with a Pulsed Glow Discharge
    Ganeev, Aleksander
    Titova, Anna
    Korotetski, Boris
    Gubal, Anna
    Solovyev, Nikolay
    Vyacheslavov, Alexander
    Iakovleva, Evgenia
    Sillanpaa, Mika
    ANALYTICAL LETTERS, 2019, 52 (04) : 671 - 684
  • [38] Direct manganese (Mn) speciation in solid state materials by pulsed glow discharge time-of-flight mass spectrometry
    Zhang, Na
    King, Fred L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1489 - 1497
  • [39] Analysis of thin impurity doped layers in anodic alumina and anodic tantala films by glow discharge time-of-flight mass spectrometry
    Molchan, I. S.
    Thompson, G. E.
    Skeldon, P.
    Trigoulet, N.
    Tempez, A.
    Chapon, P.
    TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING, 2010, 88 (03): : 154 - 157
  • [40] A comparison of non-pulsed radiofrequency and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Michler, J.
    Hohl, M.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1373 - 1381