Depth-profile analysis of thermoelectric layers on Si wafers by pulsed r.f. glow discharge time-of-flight mass spectrometry

被引:14
|
作者
Reinsberg, K. -G. [1 ]
Schumacher, C. [2 ]
Tempez, A. [3 ]
Nielsch, K. [2 ]
Broekaert, J. A. C. [1 ]
机构
[1] Univ Hamburg, Inst Inorgan & Appl Chem, D-20146 Hamburg, Germany
[2] Univ Hamburg, Inst Appl Phys, D-20355 Hamburg, Germany
[3] HORIBA Jobin Yvon, F-91160 Longjumeau, France
关键词
Thermoelectrics; Pulsed r.f. glow discharge; Time-of-flight mass spectrometry; Depthprofiling; BISMUTH TELLURIDE; ELECTRODEPOSITION; OPTIMIZATION; FILMS;
D O I
10.1016/j.sab.2012.06.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work the depth-profile analysis of thermoelectric layers deposited on Au and Cr covered Si wafers with the aid of pulsed radiofrequency glow discharge time-of-flight mass spectrometry (pulsed RF-GD-TOFMS also called plasma profiling TOFMS (PP-TOFMS (TM))) is described. For thermoelectric materials the depth resolutions obtained with both PP-TOFMS and secondary ion mass spectrometry (SIMS) are shown to be well comparable and in the order of the roughness of the corresponding layers (between 20 and 3700 nm). With both methods a direct solid analysis without any preparation steps is possible. In addition, the analysis of the samples with PP-TOFMS proved to be faster by a factor of 26 compared to SIMS, as sputtering rates were found to be 80 nm s(-1) and 3 nm s(-1), respectively. For the analyzed samples the results of PP-TOFMS and SIMS show that a homogeneous deposition was obtained. Quantitative results for all samples could also be obtained directly by PP-TOFMS when the stoichiometry of one sample was determined beforehand for instance by inductively coupled plasma optical emission spectrometry (ICP-OES) and scanning electron microscopy energy dispersive X-ray fluorescence spectrometry (SEM-EDX). For Bi2Te3 the standard deviation for the main component concentrations within one sample then is found to be between 1.1% and 1.9% and it is 3.6% from sample to sample. For Sb2Te3 the values within one sample are from 1.7% to 42% and from sample to sample 5.3%, respectively. (C) 2012 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [41] Consideration of a millisecond pulsed glow discharge time-of-flight mass spectrometer for concurrent elemental and molecular analysis
    Steiner, RE
    Lewis, CL
    Majidi, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1537 - 1541
  • [42] Influence of discharge parameters on real-time chemical speciation for gas chromatography pulsed glow discharge plasma time-of-flight mass spectrometry
    Lewis, CL
    Moser, MA
    Hang, W
    Dale, DE
    Hassell, DC
    Majidi, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (06) : 629 - 636
  • [43] Characterization of a simple glow discharge coupled to a time of flight mass spectrometer for in-depth profile analysis
    Pisonero, J
    Costa, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1126 - 1131
  • [44] Depth Profile Analysis of Molybdenum Disulfide Film by Glow Discharge Mass Spectrometry
    Wang, Mengli
    Zhao, Bin
    Zhuo, Shangjun
    Zhu, Yueqin
    Huang, Lei
    Qian, Rong
    ATOMIC SPECTROSCOPY, 2021, 42 (04) : 183 - 189
  • [45] GLOW-DISCHARGE MASS-SPECTROMETRY FOR SURFACE AND DEPTH PROFILE ANALYSIS
    KAY, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, : 89 - 89
  • [46] Isotope dilution mass spectrometry for quantitative elemental analysis of powdered samples by radiofrequency pulsed glow discharge time of flight mass spectrometry
    Alvarez-Toral, Aitor
    Fernandez, Beatriz
    Malherbe, Julien
    Claverie, Fanny
    Molloy, John L.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    TALANTA, 2013, 115 : 657 - 664
  • [47] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Sola-Vazquez, Auristela
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (09) : 2771 - 2777
  • [48] Evaluation of pulsed radiofrequency glow discharge time-of-flight mass spectrometry for precious metal determination in lead fire assay buttons
    Compernolle, Sien
    Pisonero, Jorge
    Bordel, Nerea
    Wambeke, Dorine
    De Raedt, Ine
    Kimpe, Kristof
    Sanz-Medel, Alfredo
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 129 - 133
  • [49] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Auristela Solà-Vázquez
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2771 - 2777
  • [50] Direct FexOy speciation in solid state materials by pulsed millisecond radio frequency glow discharge time-of-flight mass spectrometry
    Gu, Guodong
    DeJesus, Megan
    King, Fred L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (04) : 816 - 821