Evaluation of Uniformity and Stability of Frozen Mixed Serum Potassium Candidate Reference Materials

被引:0
|
作者
Zhang, Rui [1 ]
Zhang, Dan [1 ]
Wang, Qingtao [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Clin Lab, 8 Gongtinan Rd, Beijing 100020, Peoples R China
[2] Beijing Ctr Clin Labs, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
potassium; candidate reference material; uniformity; stability; TRACEABILITY; STANDARDIZATION;
D O I
10.7754/Clin.Lab.2019.190803
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We tested the uniformity and stability of candidate reference materials (RMs) for serum potassium and aimed to design RMs with better quality that can meet all clinical test requirements and effectively solve the quantity traceability transfer problem. Methods: Three levels of frozen mixed serum potassium candidate RMs were prepared and packed in freezing tubes. RMs were determined in triplicate in 10 vials randomly selected from each level. A one-way analysis of variance was used to evaluate the uniformity using a ratio of the mean squares among groups to mean squares within groups F < F-0.05 as the criteria. Stability was studied by synchronization; the short-term stability of the serum potassium in the transport conditions was observed for 30, 15, and 7 days at refrigeration (2 - 8 degrees C), room temperature (18 - 25 degrees C), and 37 degrees C, respectively. By linear regression analysis of variance, the straight line was used as an empirical model. The criterion for judging is vertical bar b1 vertical bar < t(0.95, n - 2).S-b1. Results: Based on the statistical analysis using SPSS 17, the F values for the homogeneity tests of each level of the frozen mixed serum potassium RMs were 0.247, 0.117, and 0.162. These values were less than F-0.05(9,F- 20) = 2.39. When the short-term stability of the serum potassium was observed for 30, 12, and 4 days at 2 - 8 degrees C, room temperature, and 37 degrees C, respectively, vertical bar b1 vertical bar < t(0.95, n - 2).S-b1, and instability was not observed. Conclusions: The three levels of the frozen mixed serum potassium RMs have good uniformity. At 2 - 8 degrees C, room temperature, and 37 degrees C, the stability can be ensured for at least 30, 12, and 4 days, respectively. The serum potassium candidate RMs are sufficiently stable under these transportation conditions.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 50 条
  • [1] Preparation of Commutable Frozen Human Serum Candidate Reference Materials for Standardization of Sodium Measurements
    Zhang, Rui
    Zhang, Shunli
    Wang, Qingtao
    CLINICAL LABORATORY, 2017, 63 (7-8) : 1243 - 1250
  • [2] EVALUATION OF THE STABILITY AND HOMOGENEITY OF REFERENCE MATERIALS
    CALAM, DH
    DAS, REG
    ANNALES DE BIOLOGIE CLINIQUE, 1993, 51 (3-5) : 334 - 335
  • [3] Standardization of immunoassays for measurement of myoglobin in serum. Phase 1: Evaluation of candidate secondary reference materials
    Panteghini, M
    Linsinger, T
    Wu, AHB
    Dati, F
    Apple, FS
    Christenson, RH
    Mair, J
    Schimmel, H
    CLINICA CHIMICA ACTA, 2004, 341 (1-2) : 65 - 72
  • [4] Preparation, stability and commutability of candidate reference materials for lactate dehydrogenase (LDH)
    Guo, Qi
    Zhu, Zejian
    Wang, Jing
    Huang, Wei
    Zhang, Chao
    Zeng, Jie
    Zhao, Haijian
    Qi, Tianqi
    Zhou, Weiyan
    Zhang, Tianjiao
    Zhang, Chuanbao
    Xiao, Fei
    CLINICAL BIOCHEMISTRY, 2021, 91 : 45 - 51
  • [5] DEVELOPMENT OF HUMAN-SERUM REFERENCE MATERIALS TO UNIFY SODIUM AND POTASSIUM RESULTS IN SERUM TO THEIR NATIONAL REFERENCE SYSTEMS
    KUS, DM
    MILLER, R
    BOWERS, GN
    KOCH, W
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1130 - 1130
  • [6] CLINICAL EVALUATION OF BENDROFLUMETHIAZIDE WITH SPECIAL REFERENCE TO SERUM POTASSIUM LEVELS
    SOFFE, AM
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1962, 4 (12): : 640 - +
  • [7] A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry
    Yan, Ying
    Han, Bingqing
    Zeng, Jie
    Zhou, Weiyan
    Zhang, Tianjiao
    Zhang, Jiangtao
    Chen, Wenxiang
    Zhang, Chuanbao
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (10) : 1517 - 1522
  • [8] Preparation and evaluation of candidate, certified reference materials (CRMs) for nutrients in seawater
    Smith, Kerry M.
    Wells, David E.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07): : 708 - 717
  • [9] Thermocyclic stability of candidate Seebeck coefficient standard reference materials at high temperature
    Martin, Joshua
    Winnie Wong-Ng
    Caillat, Thierry
    Yonenaga, I.
    Green, Martin L.
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (19)
  • [10] Candidate reference measurement procedure based on HPAEC-PAD for the development of certified reference materials for monosaccharides in serum
    Min-Seon Seo
    Ji-Seon Jeong
    Mariam M. Abady
    Ha-Jeong Kwon
    Analytical and Bioanalytical Chemistry, 2021, 413 : 5517 - 5527