Preparation of Commutable Frozen Human Serum Candidate Reference Materials for Standardization of Sodium Measurements

被引:0
|
作者
Zhang, Rui [1 ]
Zhang, Shunli [1 ]
Wang, Qingtao [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Clin Lab, 8 Gongtinan Rd, Beijing 100020, Peoples R China
[2] Beijing Ctr Clin Labs, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
sodium; candidate reference materials; homogeneity; stability; commutability; value assignment; ION CHROMATOGRAPHY; METROLOGICAL TRACEABILITY; ELECTROLYTE DISTURBANCES; LABORATORY MEDICINE; POTASSIUM;
D O I
10.7754/Clin.Lab.2017.170205
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The measurement of serum sodium is important in the diagnosis of diseases. However, the accuracy and comparability of results in clinical laboratories are not ideal. The aim of this study was to prepare the candidate reference materials (RMs) to standardize serum sodium measurements. Methods: Fresh sera without hemolysis, lipemia, and choloplania were collected and packed in the cryovials. According to ISO Guide 35, the homogeneity and stability were tested. The value was assigned by transfer from the National Institute of Standards and Technology (NIST) SRM919b using the reference method of ion chromatography (IC) and uncertainty was calculated. The commutability of candidate RMs were observed between the reference method and the two analyzed systems and then distributed to 47 laboratories to apply in routine assays. Results: The F values of the homogeneity test were less than 405; stability can last at least 12 months, 30 days, 15 days, and 7 days at -80 degrees C, 2 - 8 degrees C, room temperature (20 - 24 degrees C), and 37 degrees C, respectively. The results of three levels of candidate RMs for sodium were (159.00 +/- 2.70), (139.16 +/- 2.57), and (124.71 +/- 3.12) mmol/L; coordinate dots of candidate RMs were all within the 95% confidence interval range of a 25-serum regression line. More than 76.6% of laboratories were within a bias of +/- 1.5% from the target values. Conclusions: The homogeneity, stability, and commutability of candidate RMs all meet the requirement, and the target values are assigned accurately. These new RMs of sodium in the human serum pool can be used to set up the traceability chain to improve the comparability of measurement results.
引用
收藏
页码:1243 / 1250
页数:8
相关论文
共 50 条
  • [1] FROZEN HUMAN SERUM REFERENCE MATERIAL FOR STANDARDIZATION OF SODIUM AND POTASSIUM MEASUREMENTS IN SERUM OR PLASMA BY ION-SELECTIVE ELECTRODE ANALYZERS
    GUNARATNA, PC
    KOCH, WF
    PAULE, RC
    CORMIER, AD
    DORAZIO, P
    GREENBERG, N
    OCONNELL, KM
    MALENFANT, A
    OKORODUDU, AO
    MILLER, R
    KUS, DM
    BOWERS, GN
    CLINICAL CHEMISTRY, 1992, 38 (08) : 1459 - 1465
  • [2] Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: Study within the framework of the Dutch project "Calibration 2000"
    Cobbaert, C
    Weykamp, C
    Baadenhuijsen, H
    Kuypers, A
    Lindemans, J
    Jansen, R
    CLINICAL CHEMISTRY, 2002, 48 (09) : 1526 - 1538
  • [3] A candidate reference method and multiple commutable control materials for serum 25-hydroxyvitamin D measurement
    Zhang, Li
    Long, Qichen
    Zhang, Jiangtao
    Zeng, Qingzhang
    Zhao, Haijian
    Chen, Wenxiang
    Zhang, Tianjiao
    Zhang, Chuanbao
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (12)
  • [4] Evaluation of Uniformity and Stability of Frozen Mixed Serum Potassium Candidate Reference Materials
    Zhang, Rui
    Zhang, Dan
    Wang, Qingtao
    CLINICAL LABORATORY, 2020, 66 (04) : 595 - 601
  • [5] Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
    Xia, ChangYu
    Liu, Ou
    Wang, LanZhen
    Xu, GuoBing
    ANNALS OF LABORATORY MEDICINE, 2012, 32 (04) : 243 - 249
  • [6] Provisional standardization of hepcidin assays: creating a traceability chain with a primary reference material, candidate reference method and a commutable secondary reference material
    Diepeveen, Laura E.
    Laarakkers, Coby M. M.
    Martos, Gustavo
    Pawlak, Marta E.
    Uguz, Fatih F.
    Verberne, Kim E. S. A.
    van Swelm, Rachel P. L.
    Klaver, Siem
    de Haan, Anton F. J.
    Pitts, Kelly R.
    Bansal, Sukhvinder S.
    Abbas, Ioana M.
    Fillet, Marianne
    Lefebvre, Thibaud
    Geurts-Moespot, Anneke J.
    Girelli, Domenico
    Castagna, Annalisa
    Herkert, Matthias
    Itkonen, Outi
    Olbina, Gordana
    Tomosugi, Naohisa
    Westerman, Mark E.
    Delatour, Vincent
    Weykamp, Cas W.
    Swinkels, Dorine W.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (06) : 864 - 872
  • [7] Molecular Reference Materials for Standardization of Allergen Measurements
    Wunschmann, Sabina
    Prtorich, Kristie N.
    Minichino, Cathy
    Cerritos, Heaven
    Vailes, Lisa D.
    Chapman, Martin D.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2016, 137 (02) : AB24 - AB24
  • [8] A CANDIDATE REFERENCE METHOD FOR COUPLED SODIUM-WATER DETERMINATION IN HUMAN SERUM
    VANSUIJLEN, JDE
    BERREVOETS, CA
    LEIJNSE, B
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1990, 28 (11): : 817 - 824
  • [9] Standardization of immunoassays for measurement of myoglobin in serum. Phase 1: Evaluation of candidate secondary reference materials
    Panteghini, M
    Linsinger, T
    Wu, AHB
    Dati, F
    Apple, FS
    Christenson, RH
    Mair, J
    Schimmel, H
    CLINICA CHIMICA ACTA, 2004, 341 (1-2) : 65 - 72
  • [10] PREPARATION OF 12 CANDIDATE AGRICULTURAL REFERENCE MATERIALS
    IHNAT, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (06): : 539 - 545