Standardization of immunoassays for measurement of myoglobin in serum. Phase 1: Evaluation of candidate secondary reference materials

被引:17
|
作者
Panteghini, M [1 ]
Linsinger, T
Wu, AHB
Dati, F
Apple, FS
Christenson, RH
Mair, J
Schimmel, H
机构
[1] Azienda Osped Spedali Civili, Lab Anal Chim Clin 1, I-25125 Brescia, Italy
[2] Inst Ref Mat & Measurements, Geel, Belgium
[3] Hartford Hosp, Dept Pathol & Lab Med, Hartford, CT USA
[4] IVD Consulting, Marburg, Germany
[5] Hennepin Cty Med Ctr, Dept Lab Med & Pathol, Minneapolis, MN USA
[6] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[7] Univ Maryland, Med Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[8] Univ Innsbruck, Sch Med, Div Cardiol, Dept Internal Med, Innsbruck, Austria
关键词
myoglobin; standardization; commutability; reference materials;
D O I
10.1016/j.cccn.2003.10.030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Myoglobin is a low-molecular weight protein present in the cytosol of striated muscles. Its concentrations in serum can be measured by immunoassays and are used as an early indicator of myocardial necrosis. Since variability among commercial myoglobin assays exists, standardization of myoglobin assays is needed. Methods: An international collaborative study was organized with the involvement of seven companies using 12 different automated platforms for measuring myoglobin. Five candidate secondary, i.e., matrixed, reference materials were assayed in relation to linearity, imprecision, recovery rate and commutability to demonstrate a possible identity between the materials and the usual routine serum samples. Results: One Iyophilized candidate material (human heart myoglobin in human serum) was selected as the most suitable secondary reference material, based on the criteria examined. Used as a calibrator a posteriori, the bias between the various myoglobin assays for a frozen human serum pool was reduced from 32% to 13%. Conclusion: This study provides the basis for the selection of an internationally recognized secondary reference material. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 35 条
  • [1] Standardization of immunoassays for measurement of high-sensitivity C-reactive protein. Phase I: Evaluation of secondary reference materials
    Kimberly, MM
    Vesper, HW
    Caudill, SP
    Cooper, GR
    Rifai, N
    Dati, F
    Myers, GL
    CLINICAL CHEMISTRY, 2003, 49 (04) : 611 - 616
  • [2] Commutability Assessment of Candidate Reference Materials for Lipoprotein(a) by Comparison of a MS-based Candidate Reference Measurement Procedure with Immunoassays
    Dikaios, Ioannis
    Althaus, Harald
    Angles-Cano, Eduardo
    Ceglarek, Uta
    Coassin, Stefan
    Cobbaert, Christa M.
    Delatour, Vincent
    Dieplinger, Benjamin
    Grimmler, Matthias
    Hoofnagle, Andrew N.
    Kostner, Gerhard M.
    Kronenberg, Florian
    Kuklenyik, Zsusanna
    Lyle, Alicia N.
    Prinzing, Urban
    Ruhaak, L. Renee
    Scharnagl, Hubert
    Vesper, Hubert W.
    Deprez, Liesbet
    CLINICAL CHEMISTRY, 2023, 69 (03) : 262 - 272
  • [3] Preparation of Commutable Frozen Human Serum Candidate Reference Materials for Standardization of Sodium Measurements
    Zhang, Rui
    Zhang, Shunli
    Wang, Qingtao
    CLINICAL LABORATORY, 2017, 63 (7-8) : 1243 - 1250
  • [4] Preparation of highly purified monomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays
    Itoh, Yoshihisa
    Ichihara, Kiyoshi
    Kishi, Kouji
    Hosogaya, Shigemi
    Yamada, Toshiyuki
    CLINICA CHIMICA ACTA, 2012, 413 (1-2) : 175 - 181
  • [5] Development of a candidate reference measurement procedure for global standardization of serum/plasma apolipoproteins, including apo(a)
    Ruhaak, R.
    Kuklenyik, Z.
    Dittrich, J.
    Ceglarek, U.
    Cobbaert, C.
    CLINICA CHIMICA ACTA, 2019, 493 : S197 - S198
  • [6] Standardization of cardiac troponin I assays: pilot evaluation of ten candidate reference materials.
    Kahn, SE
    Apple, FS
    Bodor, GS
    Panteghini, M
    Welch, MH
    Wu, AHB
    Dalluge, J
    Bunk, D
    Christenson, RH
    CLINICAL CHEMISTRY, 2000, 46 (06) : A89 - A89
  • [7] Evaluation of Uniformity and Stability of Frozen Mixed Serum Potassium Candidate Reference Materials
    Zhang, Rui
    Zhang, Dan
    Wang, Qingtao
    CLINICAL LABORATORY, 2020, 66 (04) : 595 - 601
  • [8] Successful preparation of serum-based secondary reference material for standardization of total prostate-specific antigen (PSA) immunoassays
    Kano, S
    Ishibashi, M
    Kuwa, K
    Itoh, Y
    Tani, W
    Shimazu, K
    Abe, K
    Fujihashi, K
    Yoshikai, T
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 507 - 511
  • [9] Candidate reference measurement procedure based on HPAEC-PAD for the development of certified reference materials for monosaccharides in serum
    Min-Seon Seo
    Ji-Seon Jeong
    Mariam M. Abady
    Ha-Jeong Kwon
    Analytical and Bioanalytical Chemistry, 2021, 413 : 5517 - 5527
  • [10] Development of an LC-MRM-MS-Based Candidate Reference Measurement Procedure for Standardization of Serum Apolipoprotein (a) Tests
    Ruhaak, L. Renee
    Romijn, Fred P. H. T. M.
    Brkovic, Ilijana Begcevic
    Kuklenyik, Zsusanna
    Dittrich, Julia
    Ceglarek, Uta
    Hoofnagle, Andrew N.
    Althaus, Harald
    Angles-Cano, Eduardo
    Coassin, Stefan
    Delatour, Vincent
    Deprez, Liesbet
    Dikaios, Ioannis
    Kostner, Gerhard M.
    Kronenberg, Florian
    Lyle, Alicia
    Prinzing, Urban
    Vesper, Hubert W.
    Cobbaert, Christa M.
    Int Federation Clinical Chem Lab Med Working Grp Apolipoproteins Mass Spectrometry
    CLINICAL CHEMISTRY, 2023, 69 (03) : 251 - 261