Evaluation of Uniformity and Stability of Frozen Mixed Serum Potassium Candidate Reference Materials

被引:0
|
作者
Zhang, Rui [1 ]
Zhang, Dan [1 ]
Wang, Qingtao [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Clin Lab, 8 Gongtinan Rd, Beijing 100020, Peoples R China
[2] Beijing Ctr Clin Labs, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
potassium; candidate reference material; uniformity; stability; TRACEABILITY; STANDARDIZATION;
D O I
10.7754/Clin.Lab.2019.190803
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We tested the uniformity and stability of candidate reference materials (RMs) for serum potassium and aimed to design RMs with better quality that can meet all clinical test requirements and effectively solve the quantity traceability transfer problem. Methods: Three levels of frozen mixed serum potassium candidate RMs were prepared and packed in freezing tubes. RMs were determined in triplicate in 10 vials randomly selected from each level. A one-way analysis of variance was used to evaluate the uniformity using a ratio of the mean squares among groups to mean squares within groups F < F-0.05 as the criteria. Stability was studied by synchronization; the short-term stability of the serum potassium in the transport conditions was observed for 30, 15, and 7 days at refrigeration (2 - 8 degrees C), room temperature (18 - 25 degrees C), and 37 degrees C, respectively. By linear regression analysis of variance, the straight line was used as an empirical model. The criterion for judging is vertical bar b1 vertical bar < t(0.95, n - 2).S-b1. Results: Based on the statistical analysis using SPSS 17, the F values for the homogeneity tests of each level of the frozen mixed serum potassium RMs were 0.247, 0.117, and 0.162. These values were less than F-0.05(9,F- 20) = 2.39. When the short-term stability of the serum potassium was observed for 30, 12, and 4 days at 2 - 8 degrees C, room temperature, and 37 degrees C, respectively, vertical bar b1 vertical bar < t(0.95, n - 2).S-b1, and instability was not observed. Conclusions: The three levels of the frozen mixed serum potassium RMs have good uniformity. At 2 - 8 degrees C, room temperature, and 37 degrees C, the stability can be ensured for at least 30, 12, and 4 days, respectively. The serum potassium candidate RMs are sufficiently stable under these transportation conditions.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 50 条
  • [31] Stability study and uncertainty evaluation of CO2 certified reference materials for greenhouse gases monitoring
    Durbiano, F.
    Pennecchi, F. R.
    Rolle, F.
    Pavarelli, S.
    Sega, M.
    MEASUREMENT, 2024, 232
  • [32] Development of Triglyceride Certified Reference Materials in Human Frozen Serum Using Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry
    Lee, Sun Young
    Kim, Kwonseong
    Kwon, Hyun Soo
    Kim, Young Eun
    Kim, Ki Young
    Jeong, Ji-Seon
    Oh, Han Bin
    Kim, Tae Young
    Hong, Jongki
    Kang, Dukjin
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2019, 40 (05) : 418 - 423
  • [33] EVALUATION OF FROZEN VS FRESH SERUM SAMPLES USING THE DESIGNATED COMPARISON METHOD FOR HDL CHOLESTEROL IN THE CHOLESTEROL REFERENCE METHOD LABORATORY NETWORK
    KIMBERLY, MM
    WAYMACK, PP
    SMITH, SJ
    CLINICAL CHEMISTRY, 1995, 41 (06) : S136 - S136
  • [34] Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum
    Botelho, Julianne Cook
    Ribera, Ashley
    Cooper, Hans C.
    Vesper, Hubert W.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 11123 - 11129
  • [35] Commutability evaluation of candidate reference materials and ERM-DA470k/IFCC for immunoglobulin M using two international approaches
    Sang, Lu
    Wu, Chunying
    Chen, Huijuan
    Liu, Wei
    Huang, Dawei
    Yang, Xi
    Guo, Xinrui
    Cui, Ruifang
    Wang, Ning
    Zhang, Rui
    Yue, Yuhong
    Guo, Hong
    Wang, Minghao
    Miao, Yutong
    Wang, Qingtao
    Zhang, Shunli
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2023, 37 (13-14)
  • [36] Validation of candidate reference methods based on ion chromatography for determination of total sodium, potassium, calcium and magnesium in serum through comparison with flame atomic emission and absorption spectrometry
    Thienpont, LM
    VanNuwenborg, JE
    Reinauer, H
    Stockl, D
    CLINICAL BIOCHEMISTRY, 1996, 29 (06) : 501 - 508
  • [37] A COUPLED-ENZYME EQUILIBRIUM METHOD FOR MEASURING UREA IN SERUM - OPTIMIZATION AND EVALUATION OF THE AACC STUDY-GROUP ON UREA CANDIDATE REFERENCE METHOD
    SAMPSON, EJ
    BAIRD, MA
    BURTIS, CA
    SMITH, EM
    WITTE, DL
    BAYSE, DD
    CLINICAL CHEMISTRY, 1980, 26 (07) : 816 - 826
  • [38] Evaluation of a candidate reference measurement procedure for serum free testosterone based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry
    Thienpont, LM
    Van Uytfanghe, K
    Stöckl, D
    Kaufman, JM
    Fiers, T
    Ross, HA
    CLINICAL CHEMISTRY, 2004, 50 (06) : A93 - A93
  • [39] Evaluation of a candidate reference measurement procedure for serum free testosterone based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry
    Van Uytfanghe, K
    Stöckl, D
    Kaufman, JM
    Fiers, T
    Ross, HA
    De Leenheer, AP
    Thienpont, LM
    CLINICAL CHEMISTRY, 2004, 50 (11) : 2101 - 2110
  • [40] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Bei Xu
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1087 - 1094