Commutability evaluation of candidate reference materials and ERM-DA470k/IFCC for immunoglobulin M using two international approaches

被引:1
|
作者
Sang, Lu [1 ]
Wu, Chunying [2 ]
Chen, Huijuan [1 ]
Liu, Wei [2 ]
Huang, Dawei [3 ]
Yang, Xi
Guo, Xinrui [4 ]
Cui, Ruifang [5 ]
Wang, Ning [6 ]
Zhang, Rui [7 ]
Yue, Yuhong [7 ]
Guo, Hong [8 ]
Wang, Minghao [6 ]
Miao, Yutong [6 ]
Wang, Qingtao [7 ]
Zhang, Shunli [7 ]
机构
[1] Beijing Huairou Hosp, Dept Clin Lab, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Luhe Hosp, Dept Clin Lab, Beijing, Peoples R China
[3] Beijing Longfu Hosp, Dept Clin Lab, Beijing, Peoples R China
[4] China Japan Friendship Hosp, Dept Resp & Crit Care Med, Beijing, Peoples R China
[5] Changzhi Med Coll, Dept Clin Lab, Heping Hosp, Changzhi, Peoples R China
[6] Capital Med Univ, Beijing Chaoyang Hosp, Dept Clin Lab, Clin Med Coll 3, Beijing, Peoples R China
[7] Capital Med Univ, Beijing Chaoyang Hosp, Beijing Ctr Clin Labs, Dept Clin Lab,Clin Med Coll 3, Beijing 100020, Peoples R China
[8] Changzhi Med Coll, Dept Clin Lab, Heji Hosp, Changzhi, Peoples R China
关键词
candidate reference materials; commutability; ERM-DA470k; IFCC; frozen pooled human serum; IgM; WORKING GROUP RECOMMENDATIONS; STANDARDIZATION; DIFFERENCE; POOLS; BIAS;
D O I
10.1002/jcla.24955
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BackgroundThis study aimed to assess the commutability of frozen pooled human serum (PHS), high concentration of Immunoglobulin M (IgM) pure diluted materials (HPDM), commercialized pure materials (CPM), and dilutions of ERM-DA470k/IFCC in IgM detection using the CLSI and IFCC approaches, to support standardization or harmonization of IgM measurement. MethodsTwenty-four serum samples, relevant reference materials (PHS, HPDM, CPM), and different ERM-DA470k/IFCC dilutions were analyzed in triplicate using six routine methods. The commutability of the relevant reference materials was carried out following CLSI EP30-A and IFCC bias analysis. ResultsAccording to the CLSI approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 13, 15, 13, and 8 of 15 assay combinations, respectively. Using the IFCC approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 11, 9, 15, and 10 of 15 assay combinations, respectively. The ERM-DA470k/IFCC dilutions with D-PBS and RPMI-1640 Medium were commutable on 13 of 15 assay combinations according to CLSI and were commutable on all 15 assay combinations using IFCC approach. ConclusionsHigh concentration of PHS were commutable on all six detection systems using the CLSI approach. Low and medium concentration of PHS showed unsatisfied commutability. HPDM, not CPM have good commutability, has the potential to become reference materials. ERM-DA470k/IFCC diluted with different medium showed different commutability.
引用
收藏
页数:9
相关论文
共 3 条
  • [1] Commutability of the ERM-DA470k Reference Material for two assays measuring serum albumin using immunochemical principles
    Infusino, Ilenia
    Braga, Federica
    Valente, Cristina
    Panteghini, Mauro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) : 1383 - 1384
  • [2] Characterization of the New Serum Protein Reference Material ERM-DA470k/IFCC: Value Assignment by Immunoassay
    Zegers, Ingrid
    Keller, Thomas
    Schreiber, Wiebke
    Sheldon, Joanna
    Albertini, Riccardo
    Blirup-Jensen, Soren
    Johnson, Myron
    Trapmann, Stefanie
    Emons, Hendrik
    Merlini, Giampaolo
    Schimmel, Heinz
    CLINICAL CHEMISTRY, 2010, 56 (12) : 1880 - 1888
  • [3] EVALUATION OF COMMUTABILITY OF THE ERM-DA 470K REFERENCE MATERIAL FOR TWO ALBUMIN ASSAYS USING IMMUNOCHEMICAL PRINCIPLES
    Infusino, I.
    Braga, F.
    Valente, C.
    Panteghini, M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S805 - S805