Evaluation of Uniformity and Stability of Frozen Mixed Serum Potassium Candidate Reference Materials

被引:0
|
作者
Zhang, Rui [1 ]
Zhang, Dan [1 ]
Wang, Qingtao [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Clin Lab, 8 Gongtinan Rd, Beijing 100020, Peoples R China
[2] Beijing Ctr Clin Labs, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
potassium; candidate reference material; uniformity; stability; TRACEABILITY; STANDARDIZATION;
D O I
10.7754/Clin.Lab.2019.190803
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We tested the uniformity and stability of candidate reference materials (RMs) for serum potassium and aimed to design RMs with better quality that can meet all clinical test requirements and effectively solve the quantity traceability transfer problem. Methods: Three levels of frozen mixed serum potassium candidate RMs were prepared and packed in freezing tubes. RMs were determined in triplicate in 10 vials randomly selected from each level. A one-way analysis of variance was used to evaluate the uniformity using a ratio of the mean squares among groups to mean squares within groups F < F-0.05 as the criteria. Stability was studied by synchronization; the short-term stability of the serum potassium in the transport conditions was observed for 30, 15, and 7 days at refrigeration (2 - 8 degrees C), room temperature (18 - 25 degrees C), and 37 degrees C, respectively. By linear regression analysis of variance, the straight line was used as an empirical model. The criterion for judging is vertical bar b1 vertical bar < t(0.95, n - 2).S-b1. Results: Based on the statistical analysis using SPSS 17, the F values for the homogeneity tests of each level of the frozen mixed serum potassium RMs were 0.247, 0.117, and 0.162. These values were less than F-0.05(9,F- 20) = 2.39. When the short-term stability of the serum potassium was observed for 30, 12, and 4 days at 2 - 8 degrees C, room temperature, and 37 degrees C, respectively, vertical bar b1 vertical bar < t(0.95, n - 2).S-b1, and instability was not observed. Conclusions: The three levels of the frozen mixed serum potassium RMs have good uniformity. At 2 - 8 degrees C, room temperature, and 37 degrees C, the stability can be ensured for at least 30, 12, and 4 days, respectively. The serum potassium candidate RMs are sufficiently stable under these transportation conditions.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 50 条
  • [41] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1087 - 1094
  • [42] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [43] Evaluation of material waste, dimensional stability, and detail reproduction of polyvinyl siloxane impression materials mixed with different mixing tips
    Maluly-Proni, Ana Teresa
    Delben, Juliana Aparecida
    Fraga Briso, Andre Luiz
    Marson, Fabiano Carlos
    dos Santos, Paulo Henrique
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (05): : 759 - 764
  • [44] Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: Study within the framework of the Dutch project "Calibration 2000"
    Cobbaert, C
    Weykamp, C
    Baadenhuijsen, H
    Kuypers, A
    Lindemans, J
    Jansen, R
    CLINICAL CHEMISTRY, 2002, 48 (09) : 1526 - 1538
  • [45] Candidate Reference Measurement Procedures for Chloride, Potassium, Sodium, Calcium, Magnesium, and Lithium by Inductively Coupled Plasma (Isotope Dilution) Sector Field Mass Spectrometry (ICP-(ID) SFMS) in Serum
    Kramer, U.
    Kress, M.
    Reinauer, H.
    Spannagl, M.
    Kaiser, P.
    CLINICAL LABORATORY, 2013, 59 (9-10) : 1017 - 1029
  • [46] Evaluation and clinical application of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for serum theophylline
    Du, Yuanyuan
    Yan, Qiaofang
    Zhan, Min
    Zhang, Qiaoxuan
    Huang, Di
    Zhang, Pengwei
    Yan, Jun
    Wang, Jianbing
    Huang, Xianzhang
    Han, Liqiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (22) : 4897 - 4906
  • [47] INTERNATIONAL FEDERATION OF CLINICAL-CHEMISTRY STANDARDIZATION PROJECT FOR MEASUREMENTS OF APOLIPOPROTEINS-A-I AND APOLIPOPROTEINS-B .2. EVALUATION AND SELECTION OF CANDIDATE REFERENCE MATERIALS
    ALBERS, JJ
    MARCOVINA, SM
    KENNEDY, H
    CLINICAL CHEMISTRY, 1992, 38 (05) : 658 - 662
  • [48] Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol
    Cobbaert, C
    Mulder, PGH
    Baadenhuijsen, H
    Zwang, L
    Weykamp, CW
    Demacker, PNM
    CLINICAL CHEMISTRY, 1999, 45 (03) : 360 - 370
  • [49] Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry
    Tai, SSC
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1008 - 1014
  • [50] Measurement of serum 17-hydroxyprogesterone using isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method and evaluation of the performance for three routine methods
    Long, Qichen
    Zhang, Tianjiao
    Yan, Ying
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Li, Shuijun
    Zhang, Jiangtao
    Zeng, Qingzhang
    Zhao, Beibei
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) : 523 - 532