Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry

被引:53
|
作者
Tai, Susan S. -C. [1 ]
Xu, Bei
Welch, Michael J.
Phinney, Karen W.
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Natl Inst Metrol, Beijing 100013, Peoples R China
关键词
testosterone; reference measurement procedure; electrospray ionization; isotope dilution; liquid chromatography/tandem mass spectrometry LC/MS/MS; solid-phase extraction; liquid-liquid extraction;
D O I
10.1007/s00216-007-1355-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d(3)) were extracted from the serum matrix using a combination of solid-phase extraction and liquid-liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g(-1). Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [1] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Bei Xu
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1087 - 1094
  • [2] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [3] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [4] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411
  • [5] Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry
    Tai, SSC
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1008 - 1014
  • [6] Development and evaluation of a candidate reference measurement procedure for the determination of 19-Norandrosterone in human urine using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, SSC
    Xu, B
    Sniegoski, LT
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2006, 78 (10) : 3393 - 3398
  • [7] Development and evaluation of a reference measurement procedure for the determination of estradiol-17β in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    Tai, SSC
    Welsh, MJ
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6359 - 6363
  • [8] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Zhang, Qiaoxuan
    Han, Liqiao
    Zheng, Songbai
    Ouyang, Fen
    Wu, Xiaobin
    Yan, Jun
    Zhan, Min
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4471 - 4481
  • [9] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Qiaoxuan Zhang
    Liqiao Han
    Songbai Zheng
    Fen Ouyang
    Xiaobin Wu
    Jun Yan
    Min Zhan
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4471 - 4481
  • [10] Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Kim, Byungjoo
    Lee, Gaeho
    ANALYTICAL SCIENCES, 2007, 23 (03) : 299 - 303